Thermocouple Temperature Measuring Instrument

A thermocouple temperature tester generates a thermoelectric potential at the temperature measurement point through two different metal wires, which is then converted into a temperature reading via a circuit. It is used for real-time monitoring of surface or medium temperatures of objects and is suitable for temperature control in industrial scenarios such as ovens and injection molding machines.
Selection
When selecting, consider matching the temperature measurement range to process requirements, choosing thermocouple types suitable for media characteristics, ensuring the probe structure fits the installation environment, meeting control requirements with appropriate accuracy levels, adapting the protection rating to site conditions, and matching the response speed to dynamic changes.

Terms

Standards

Instruments

It can simultaneously measure the temperature of 8 channels, support K-type Thermocouple temperature measurement range -200~ 1300 ℃, use true color TFT-LCD display, with data recording and upper and lower limit alarm functions, Sampling rate 1.5 seconds.

$ 298.00

Four-channel configuration with K-type Thermocouple, the sampling rate can be adjusted from 1 second to 1 minute, and the thermal insulation performance can last for 60 minutes in a 500 ° C environment to achieve full temperature tracking monitoring.

$ 1014.00

Single-channel design, supports J, K, T, E, R, S, B, N-type Thermocouple Probe, internal thermistor cold junction compensation, temperature error +/- 0.21 ° C, recording interval can be flexibly set from 1 second to 18 hours.

$ 359.00

Using 16-bit AD converter and K-type Thermocouple, sampling speed 16 times per second, Measurement range -50 ° C to 1300 ° C, support Fahrenheit switching and data retention functions.

$ 104.00

Four-channel K-type Thermocouple with 0.5% accuracy, the insulation box can work continuously for 1 hour in a 300 degree environment, supports multi-rate sampling and 16000 Data storage, Stability is high and easy to operate.

$ 624.00

With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.

$ 107.00

The clamping design ensures close contact with the surface of the workpiece, Teflon wires are easy to clean and flexible and durable, the maximum Operating temperature is 300 ° C, and the lightweight structure avoids measurement interference.

$ 474.00

Four-channel K-type Thermocouple configuration, accuracy of 0.5%, insulation performance maintained at 400 ℃ for 60 minutes, support multi-rate sampling and data synchronization analysis, to ensure stable and reliable temperature mapping.

$ 940.00

The clamping design ensures good contact with the workpiece surface, the lightweight shape avoids affecting the temperature, the Teflon sheath is flexible and durable, with a maximum temperature resistance of 300 ° C, and the ceramic insulation guarantees accurate readings.

$ 523.00

8-Channel synchronous collection of temperature data, support a variety of Thermocouple types, temperature range -200~ 1800 ℃, with breaking detection and upper and lower limit alarm functions, Response speed and stable data.

$ 325.00

Four-channel synchronous acquisition, supports a variety of Thermocouple types, the temperature measurement range covers -200 to 1800 ° C, with broken couple detection function and upper and lower limit alarm settings, Fast Response and stable data.

$ 294.00

Equipped with 6 measurement channels and K-type Thermocouple, supports a wide temperature range of 0-1200 ° C, uses 3.5-inch full-color Touchscreen operation, built-in rechargeable battery can work continuously for 4 hours, storage capacity up to 250,000 measurement points.

$ 7458.00

Using 32-bit high-speed MCU and 24-bit AD chip, the inter-channel withstand voltage AC/DC 350V, the built-in 8G memory can record continuously for 97 days, and supports multi-channel independent error correction and alarm functions.

$ 1017.00

Using high aluminum liner and upper and lower left and right 4-sided heating design, temperature control accuracy up to +/- 2 ℃, equipped with K-indexing Thermocouple and secondary over-temperature protection, support timing work and thermostatic automatic shutdown.

$ 364.00

Three-sided heating method with aluminum silicate Furnace, high thermal efficiency and uniform temperature. PID control combined with K-type Thermocouple, temperature control accuracy +/- 5%, support 0~ 9999 minutes timing and phased heating.

$ 606.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.