Electrically Heated Drying Oven

The electric drying oven heats air via electric heating elements and utilizes hot air circulation to ensure uniform temperature inside the chamber. It is used to remove moisture from samples, cure coatings, or perform heat treatment. It is suitable for routine operations in laboratories, such as constant-temperature drying and aging tests of materials.
Selection
When selecting, ensure the temperature range covers experimental needs, and the temperature control accuracy meets sample requirements. The chamber volume should be determined based on the size of the samples to be processed, and the material's corrosion resistance should suit the experimental environment. Pay attention to parameters such as heating rate and temperature uniformity, and ensure the hot air circulation system is stable and reliable.

Terms

Standards

Instruments

Temperature range RT + 5~ 99 ℃, Temperature Fluctuation +/- 0.5 ℃, stainless steel liner, beaker hole can be arbitrarily changed in size, over-temperature sound and light tracking alarm to protect the sample.

$ 317.00

The cuboid studio improves the effective volume utilization rate, temperature control accuracy +/- 1 ℃, drying time is shortened by more than 40% compared with traditional equipment, and can be heated and tested in an oxygen-free or inert gas environment.

$ 730.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃; using low noise fan and hot air circulation system, dry hot air directly through the heated object; with overheating, leakage, Sensor fault alarm function.

$ 369.00

Cuboid studio improves volume utilization, drying time is reduced by more than 40%; Temperature range RT + 10~ 200 ℃, Vacuum Level 133Pa; double-decked Glass door is easy to observe, can be filled with inert gas anti-oxidation, stainless steel liner is durable and easy to clean.

$ 746.00

Air disturbance technology is used to simulate indoor air flow, equipped with 24 independent sample Chambers to prevent cross-contamination, the drying Temperature range is adjustable at RT-50 ° C, and the outer exhaust air is purified without affecting the environment.

$ 3173.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Shelf direct heating technology, each Shelf independent temperature control, Temperature Fluctuation +/- 1 ℃, heating time is shortened by more than 50%, to ensure that the drying process without oxidation, accurate and stable measurement.

$ 13294.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
The coating machine applies the adhesive layer of the plaster patch onto the backing layer.
The coating machine applies adhesive evenly onto the backing material through steps such as feeding, coating, drying, and winding, forming a stable adhesive layer.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Zero-span tensile strength tester measures the tensile strength of wet pulp.
This article introduces the method of measuring the tensile strength of wet pulp using a zero-span tensile strength tester. Traditional testing is often conducted after the pulp is dried, but testing in the wet state can more directly reflect the bonding potential between fibers.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.