Light Test Chamber

The light test chamber performs light aging tests on materials by simulating specific spectral and lighting conditions. Its principle involves using xenon or ultraviolet lamps to generate illumination, combined with temperature and humidity control, to evaluate the material's light resistance. Its function is to detect phenomena such as discoloration and chalking of samples like coatings and plastics under light exposure. It is applied in industries for quality control, such as ink lightfastness testing and paper yellowing evaluation.
Selection
When selecting a light test chamber, consider matching the light source type with testing standards: xenon lamps are suitable for full-spectrum aging, while UV lamps focus on accelerated aging. Determine the chamber volume based on sample dimensions, and ensure control accuracy meets temperature and humidity fluctuation requirements. Pay attention to irradiance calibration capabilities and energy consumption data, and make a comprehensive judgment by combining equipment maintenance cycles with the brand's technical service capabilities.

Instruments

With five adjustable light and 10~ 65 ℃ Temperature range, using equilibrating refrigeration and air circulation technology to ensure uniform temperature, built-in intelligent humidification system supports automatic replenishment of external water Tank.

$ 1400.00

With six-level adjustable light and 0.1 ℃ Temperature resolution, it can simulate the change of day and night temperature and Humidity, and supports 30 sets of program settings to ensure the safe and stable operation of the experiment.

$ 1845.00

Temperature range of 0~ 50 ℃ and light intensity of 0~ 12000LX, support five-level light regulation and 99-segment program control, using PID intelligent temperature control system and pressure equilibrating refrigeration technology to ensure long-term continuous and stable operation.

$ 2612.00

With 0~ 50 ℃ Temperature range and 0~ 18000LX Illumrination degree, using PID control technology to ensure stable temperature and humidity, support five-level light adjustment and power-off memory function.

$ 2831.00

150L volume design, Temperature range 4~ 50 ℃, Illumrination degree 0~ 12000LX, six adjustable light, can simulate day and night temperature Humidity changes, support 30 sets of program settings, independent temperature limit alarm system to ensure safe operation.

$ 2042.00

With five-level adjustable light and +/- 1 ℃ Temperature Fluctuation, using ALLCOLD equilibrate refrigeration and ALLFLOW air circulation system, support multi-stage programming control and remote monitoring to ensure a stable and efficient experimental environment.

$ 4137.00

With five-stage adjustable light and a wide Temperature range of 10~ 65 ℃, ALLCOLD equilibrate refrigeration and ALLFLOW air circulation are used to ensure uniform and stable temperature. Support multi-stage programming and RS485 connection for long-term experimental monitoring.

$ 2826.00

Mirror stainless steel liner and four-corner half-arc design for easy cleaning, three-sided light to ensure no dead ends. Temperature range 4-50 ℃, Humidity deviation +/- 5-7% RH, support 99 cycle program settings, continuous operation of not less than 360 hours.

$ 2739.00

Equipped with two sets of Compressor automatic switching to ensure long-term continuous operation, support 30-stage programming control of temperature Humidity light, light intensity 0-35000Lx six-level adjustable, mirror stainless steel liner for cleaning and disinfection.

$ 13501.00

Equipped with two sets of Compressor automatic switching to ensure long-term continuous operation, support 30-stage programming control Humidity Illumrination degree, light intensity 0~ 12000LX six-level adjustable, mirror stainless steel liner for easy cleaning and disinfection.

$ 2447.00

With microcomputer programming control, can independently set the temperature Illumrination degree, light intensity 0~ 12000LX adjustable, Temperature Fluctuation +/- 0.5 ℃, support power-off memory and internal dehumidification function to ensure a stable environment.

$ 1705.00

With full light 10~ 50 ℃ and no light 5~ 50 ℃ Temperature range, Temperature Uniformity +/- 2 ℃, Illumrination degree ≥ 2500lx, suitable for a variety of experimental needs, stable and reliable performance.

$ 975.00

Adopt ALLCOLD equilibrating refrigeration technology, equipped with automatic defrosting function, Temperature range 0~ 65 ℃, Temperature Uniformity +/- 1.5 ℃. The ALLFLOW air circulation system ensures stable temperature, and the five-stage adjustable lighting system simulates natural light changes.

$ 4424.00

Adopt equilibrate refrigeration technology, low temperature fluctuation, equipped with fluorine-free R134 refrigerant. Light intensity 0~ 10000LX five-level adjustable, Humidity range 50~ 90% RH, double door design for easy observation.

$ 2018.00

With two sets of Compressor automatic switching, support for up to several months of uninterrupted operation; Illumrination degree 0~ 30000LX adjustable, CO2 concentration 0~ 10% monitoring; Programmable control of temperature Humidity and light to meet the needs of complex experiments.

$ 6983.00