Double-compartment high-low temperature test chamber

Two-chamber high and low temperature test chambers achieve rapid temperature conversion through independent high-temperature and low-temperature chambers, utilizing refrigeration systems and heating elements to control the internal temperature environment. They are used to simulate the performance changes of products under varying temperature conditions, commonly applied in temperature resistance testing of electronic components and materials during the research and development phase.
Selection
When selecting, ensure the temperature range covers the testing requirements, the conversion time matches the product testing rhythm, and the chamber size is determined based on the sample dimensions. Consider the cooling method and the site's power supply conditions. The operation interface should be intuitive and user-friendly, and the equipment structure must facilitate maintenance and upkeep.

Terms

Standards

Instruments

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 6254.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.

$ 6770.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 5947.00

Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.

$ 9352.00

Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.

$ 5431.00

Temperature range -70~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and a variety of standard requirements.

$ 5560.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature cycle change test, suitable for aging test and material performance inspection.

$ 7109.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature, low temperature and constant temperature test, suitable for Reliability test, equipped with multiple protection devices and safety system.

$ 4818.00

Temperature control range -60~ 150 ° C, studio volume 80L, suitable for high temperature and low temperature cycle change testing, in line with a number of national standards, equipped with perfect protection devices and imported refrigeration system.

$ 5043.00

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Temperature range -20~ 150 ℃, volume 225L, stainless steel studio and high-efficiency insulation material, support high and low temperature cycle test, suitable for aging test and pRoduct performance inspection.

$ 5399.00

Temperature range -20~ 150 ℃, studio volume 408L, suitable for high temperature and low temperature Reliability test, support constant temperature test, in line with a number of national standards.

$ 6076.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!