Single-beam spectroPhotoMeter

A single-beam spectrophotometer generates a beam of light through a light source, which is then separated by a monochromator to isolate light of a specific wavelength to irradiate the sample, and a detector measures the intensity of the transmitted light. It is used to determine solution concentrations and analyze material content, as well as to detect pollutant concentrations or component levels in fields such as chemical engineering and environmental protection.
Selection
When selecting, consider that the measurement wavelength range covers the absorption peak of the analyte, the sample cell specifications match the solution volume, and the detector sensitivity meets low-concentration detection requirements. Pay attention to baseline stability to minimize errors, ensure the operation interface aligns with user habits, and evaluate maintenance costs and the availability of accessories.

Terms

Standards

Instruments

Single beam of light grating system, Wavelength range 340~ 1000nm, Light spectrum Bandwidth 4nm, sealing grating monochromator design to improve Stability and Metering accuracy, automatic adjustment 0% and 100% function to simplify operation.

$ 270.00

Single beam of light grating system, Wavelength range 340~ 1000nm, Light spectrum Bandwidth 4nm, with automatic zero and 100% function, sealing type grating monochromator mildew-proof design, improve Stability and Metering accuracy.

$ 344.00

Single beam of light Optical inspection system, Light spectrum Bandwidth 4nm, Wavelength range 340~ 1000nm, with automatic zero and 100% function, sealing grating monochromator to improve Metering accuracy and Stability.

$ 307.00

Optical inspection system with single beam of light, Light spectrum Bandwidth 4nm, Wavelength range 200-960nm, Support Transmittance, Absorbance and concentration direct reading Operating Mode, equipped with RS232 interface to connect external devices.

$ 670.00

1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.

$ 2494.00

Proportional double beam of light monitoring and Holographic grating, wavelength Precision +/- 0.5nm, stray light ≤ 0.15% T, support automatic zero adjustment and eight Sample Chamber linkage, easy and reliable operation.

$ 2252.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating and imported photoelectric converter, wavelength Precision +/- 0.5nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function.

$ 4592.00

Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.

$ 5237.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function, support a variety of data map processing.

$ 4914.00

Proportional double beam of light path and Holographic grating, stray light ≤ 0.15% T, Wavelength range 190~ 1100nm, support automatic zero adjustment and eight Sample Chamber linkage, with professional power-off protection function.

$ 2591.00

1200L/mm UV dedicated grating and proportional double beam of light design, stray light ≤ 0.03% T, equipped with 10cm sample holder and automatic octet cell, support wavelength scanning and a variety of test modes.

$ 3623.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octagonal cell sample holder to improve test efficiency, Wavelength range 190~ 1100nm coverage of a wide range of applications.

$ 3268.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octave cell sample holder to improve test efficiency, with automatic wavelength correction function and a variety of test modes.

$ 3268.00

Dual beam of light path structure with 1600L/mm holographic blazing grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with Touchscreen and dedicated Software support map data processing.

$ 5883.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.