Paper Softness Detector

The paper softness tester measures the bending resistance of paper under specific pressure by simulating the mechanical feedback of human touch. It is used to quantify the flexibility characteristics of paper, guiding the tactile adjustment and production control of products such as toilet paper and napkins.
Selection
When selecting, focus on matching the measurement range with the product's softness interval, and ensure the instrument complies with the GB/T 8942 standard. Consider the compatibility between testing speed and production capacity, and check the durability of the indenter material. Verify that data repeatability error is less than 3%, and ensure the operation interface is intuitive and user-friendly.
application

Terms

Standards

Instruments

Test speed of 1.2mm/s and press depth of 8mm, equipped with 5-20mm multi-specification narrow width sample table, slot-die parallelism error ≤ 0.05mm, to ensure accurate and reliable softness measurement.

$ 1937.00

The probe is designed with a depth of 8mm and a Probe width of 400mm, which simulates the softness of the hand. It supports a variety of slot-die width configurations. The built-in thermal printer can directly output the test results.

$ 3107.00

Single chip computer digital circuit technology, Measurement range 10~ 1000mN, Indication Error +/- 1%, with 4-bit direct reading display and printing function, Test speed 1.2 +/- 0.24mm/s, suitable for accurate detection of softness.

$ 2591.00

In accordance with IULCS. IUP 136 standard, the load is 500g, the scale range is 0.1-10 mm, the Portable design is easy to operate and maintain, and can detect the uniformity of leather Softness and site differences.

$ 1090.00

Measurement range 10~ 1000mN, Test speed 1.2mm/s, 3.5-inch color LCD display test Linear dispersion, built-in thermal printer can directly output test reports, suitable for a variety of slot-die width tests.

$ 2752.00

Micro Sensor measurement and control system to achieve automatic measurement, Measurement range 10~ 1000mN, accuracy +/- 1%, built-in thermal printer can directly output test reports, support custom slot-die width.

$ 2712.00

The probe is applied with a load of 530 +/- 10g, and the leather is pressed at a constant speed. The softness index is directly read through the electronic watch, which is suitable for testing a variety of leather types.

$ 1101.00

Response speed is improved with ARM processor, Measurement range 10-1000mN, accuracy +/- 1%, equipped with four-speed adjustable slot-die 5-20mm, support sudden power failure data saving and real-time pressure Linear dispersion display function.

$ 2533.00

Lever principle measurement device to reduce data fluctuations, equipped with High Accuracy Force Sensor, Measurement range 10~ 1000mN, accuracy 0.1mN, and built-in thermal printer directly output clear report.

$ 1873.00

Using digital DC motor to achieve stepless speed regulation of 1~ 1000mm/min, equipped with arc synchronous toothed belt and precision screw auxiliary drive system, the test accuracy can reach 1 level, and the test can be automatically completed and the maximum force value can be memorized.

$ 2510.00

Conductivity Detector principle, Measurement range 2-95%, accuracy 0.1%, Response Time only 1 second, Humidity compensation technology to ensure measurement Stability, support MAX Maximum hold and automatic shutdown function.

$ 159.00

Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.

$ 144.00

Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.

$ 1134.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00