Test speed of 1.2mm/s and press depth of 8mm, equipped with 5-20mm multi-specification narrow width sample table, slot-die parallelism error ≤ 0.05mm, to ensure accurate and reliable softness measurement.
The probe is designed with a depth of 8mm and a Probe width of 400mm, which simulates the softness of the hand. It supports a variety of slot-die width configurations. The built-in thermal printer can directly output the test results.
Single chip computer digital circuit technology, Measurement range 10~ 1000mN, Indication Error +/- 1%, with 4-bit direct reading display and printing function, Test speed 1.2 +/- 0.24mm/s, suitable for accurate detection of softness.
In accordance with IULCS. IUP 136 standard, the load is 500g, the scale range is 0.1-10 mm, the Portable design is easy to operate and maintain, and can detect the uniformity of leather Softness and site differences.
Measurement range 10~ 1000mN, Test speed 1.2mm/s, 3.5-inch color LCD display test Linear dispersion, built-in thermal printer can directly output test reports, suitable for a variety of slot-die width tests.
Micro Sensor measurement and control system to achieve automatic measurement, Measurement range 10~ 1000mN, accuracy +/- 1%, built-in thermal printer can directly output test reports, support custom slot-die width.
The probe is applied with a load of 530 +/- 10g, and the leather is pressed at a constant speed. The softness index is directly read through the electronic watch, which is suitable for testing a variety of leather types.
Response speed is improved with ARM processor, Measurement range 10-1000mN, accuracy +/- 1%, equipped with four-speed adjustable slot-die 5-20mm, support sudden power failure data saving and real-time pressure Linear dispersion display function.
Lever principle measurement device to reduce data fluctuations, equipped with High Accuracy Force Sensor, Measurement range 10~ 1000mN, accuracy 0.1mN, and built-in thermal printer directly output clear report.
Using digital DC motor to achieve stepless speed regulation of 1~ 1000mm/min, equipped with arc synchronous toothed belt and precision screw auxiliary drive system, the test accuracy can reach 1 level, and the test can be automatically completed and the maximum force value can be memorized.
Conductivity Detector principle, Measurement range 2-95%, accuracy 0.1%, Response Time only 1 second, Humidity compensation technology to ensure measurement Stability, support MAX Maximum hold and automatic shutdown function.
Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.
Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.
Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.