Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.
Laser Sensor is used to directly measure the natural vibration frequency of the belt. The size of the split probe is only 124 * 21 * 12mm, which can penetrate into the depth of 66mm. Measurement range is 10-500Hz, and it supports metric and imperial unit switching.
Laser Sensor is used to directly measure the natural vibration frequency of the belt. Measurement range is 10-800Hz. The split probe size is 124 * 21 * 12mm and can penetrate into a small space of 66mm. It supports metric and imperial unit switching.
Magnetic surface temperature measurement Probe through strong magnetic adsorption on the workpiece, small volume and light mass, Sensor and magnet insulation to ensure measurement accuracy, the highest temperature 480 ℃, especially suitable for circular workpiece surface.
Built-in Probe design, surface temperature Measurement range -40~ 80 ℃, air temperature accuracy +/- 0.5 ℃, Humidity range 0~ 100% RH, providing stable and reliable dew point monitoring.
The ring 6mm Probe design ensures good contact with the workpiece surface, the Teflon jacket is easy to clean and flexible and durable, the maximum temperature resistance is 300 ° C, and the lightweight shape avoids affecting the measurement accuracy.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control system, the studio is made of 304 stainless steel for fast and uniform heating.
Using 5MHZ Frequency and 10mm diaMeter Probe design, Measurement range 1.2-230 mm, the minimum pipe diaMeter can be measured Φ 20mm × 3mm, suitable for thickness detection in room temperature environment.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control system to achieve automatic thermostatic operation, the studio is made of 304 stainless steel, size 600 * 600 * 500mm.
Using shortwave infrared technology, temperature range 200~ 2200 ℃, accuracy +/- 2%, with laser positioning, data retention and emissivity adjustable functions, Response Time 500ms, object distance ratio 80:1.
Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.
Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, fast low consumption adjustment is convenient.