Adopt stainless steel liner and superfine Glass cotton insulation, equipped with multi-layer conductive film observation window and silicone rubber sealing. Temperature control accuracy +/- 0.5 ℃, humidity fluctuation +/- 2% RH, with independent over-temperature protection and interlocking safety device.
Using Japanese Panasonic Compressor and binary low temperature circuit system, temperature control accuracy of +/- 0.5 ℃, equipped with stainless steel humidifier and nickel-chromium alloy heater, support programmed test and data recording function, to meet the demanding environment simulation needs.
Adopting double-decked vacuum Glass observation window and SUS304 stainless steel inner box, equipped with Japanese Panasonic Compressor and PID control technology, Temperature Uniformity ≤ 2 ℃ and supports programmed multi-stage testing to meet the demanding environment simulation requirements.
Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.
Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.
The stainless steel mirror heating Chamber and intermittent continuous heating technology are used to heat the sample evenly, with a heat-resistant temperature of more than 200 ° C. Equipped with HBM Sensor, it can remember multiple sets of drying processes and support three heating modes.
Spreader 13 micron wet film thickness, application width up to 300mm, 304 stainless steel for durability and precise coating control.
Adjustable application width, with automatic Spreader function, easy to operate, Repeatability is good, suitable for a variety of samples of laboratory prepative.
The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.
The extrusion production process ensures uniform coating, with a wet film thickness of 60μm meeting the demands of precise experiments. The 304 stainless steel material is durable and easy to clean, making it suitable for diverse coating performance tests.
Using the formed pRoduction process, the wet film thickness is 6 microns, the accuracy is 0.5 microns, the cleaning is convenient and there is no worry of broken wire, to ensure the precision and durability of the coating prepative.
Wound wire design, wet film thickness 125.7 microns, coating width 300 mm, stainless steel material ensures durability and precise coating effect.
Using a wire-wound coating process, with a wet film thickness of 32.0 μm and a coating width of 300 mm, it is suitable for substrates prone to curling and convexity, enabling uniform wet film coating, with a wire diaMeter of 0.36 mm.
Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.
Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.