Using dual-channel proportional value display, knob type operation is easy, flame size can be pre-selected, equipped with flameout protection device. Detection limit K ≤ 0.004mmol/L, Na ≤ 0.008mmol/L, Response Time < 8S, high stability.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Five elements can be combined with any combination at the same time, automatic ignition and flame monitoring, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.
1KW standard blowtorch, flame height 170-190mm, support 0.1-999 seconds holding time setting, with automatic timing and high voltage ignition function, suitable for flame retardant performance testing of various cable materials.
Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, using forced convection design to heat up quickly, over-temperature automatic interruption operation to ensure safety, shelf can be moved for easy cleaning.
Temperature range RT + 10~ 200 ℃ and resolution up to 0.1 ℃, forced convection design to shorten the rapid heating drying time, with over-temperature automatic protection and fan speed regulation function, shelf can be moved for easy cleaning and maintenance.
High Accuracy microcomputer temperature controller, temperature control accuracy of +/- 1 ℃, Temperature resolution of 0.1 ℃; forced convection design makes rapid heating, drying and disinfection time shortened; with over-temperature automatic interruption function to ensure safe operation.
Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.
Temperature control accuracy +/- 1 ℃, rapid heating and over-temperature automatic interrupt function, adjustable fan Rotation speed and timing control, easy to clean the box.
The equipment adopts stainless steel structure to resist corrosion, equipped with automatic ignition and Timing function, combustion time 0~ 99.99 seconds, gas lamp Nozzle inner diaMeter 9.5mm, to ensure accurate and reliable testing.
Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation; Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃; with over-temperature alarm, leakage protection and timing functions, mirror stainless steel liner is easy to clean.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.
Using high temperature dry heat technology to destroy microbial cell protoplasm through oxidation, Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, RS-485 interface and mirror stainless steel liner to ensure disinfection effect and equipment durability.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, flexible and convenient; Internal standard channel can correct the signal to ensure stable and reliable performance.
Dual-channel proportional value shows that the sample suction and spray volume is less than 6mL/min, the Response Time is less than 8 seconds, and it has a flameout protection device, which is easy, stable and reliable to operate.
Dual channel LED digital display, Measurement accuracy, sodium detection limit ≤ 0.008mmol/L, support lithium calcium detection, using silicon Photocells, photovoltaic cells and liquefied petroleum gas fuel, sample volume is small and Sensitivity is high.