Low Constant Temperature Water Bath

The low constant temperature bath maintains stable liquid temperature inside the bath through heating and cooling systems, and is used for laboratory sample temperature control, chemical reaction regulation, material performance testing, and other applications.
Selection
When selecting, pay attention to the temperature range and fluctuation indicators, determine the tank size based on sample capacity, consider stainless steel or corrosion-resistant materials, verify the power supply and safety protection functions, and choose between compressor-type or thermoelectric constant temperature methods based on frequency of use.

Terms

Standards

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with a built-in circulating water pump to output thermostatic water flow, stainless steel structure to ensure durability and easy cleaning.

$ 367.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

Adopt stainless steel liner and microcomputer intelligent temperature control system, Temperature Fluctuation +/- 0.2 ℃, resolution 0.1 ℃, with over-temperature water cut-off alarm function, built-in circulating water pump can output thermostatic water flow.

$ 622.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

High temperature control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, equipped with circulating pump flow ≥ 4L/min, to ensure uniform water temperature, strong corrosion resistance, compact structure, suitable for a variety of experimental scenarios.

$ 302.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120min to meet different experimental needs.

$ 740.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude of 20mm, to ensure the stability and reliability of the experimental process.

$ 740.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.

$ 1317.00

Articles

Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Selection of wet film thickness gauge range and accuracy requirements for comb teeth spacing.
When selecting a wet film thickness gauges, the key considerations are the measurement range and the accuracy of the comb teeth spacing. The range should cover the coating thickness with a slight margin to avoid being too small for measurement or too large, which could reduce resolution.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.