Solubility Tester

The solubility tester observes the dissolution process of substances in solvents by controlling conditions such as temperature and stirring. It is used to determine the solubility and dissolution rate of materials in different solvents and is applied in quality control in industries such as chemical engineering and pharmaceuticals.
Selection
When selecting a solubility tester, consider matching the sample properties with the detection range, ensuring that temperature control accuracy and stirring methods meet the requirements, evaluating the ease of operation and data recording functions, and referring to practical application cases and user feedback.

Terms

Standards

Instruments

It adopts 12.7mm ultra-thin body design, is equipped with 5.5-inch large screen and 1000 sets of data storage capacity, supports automatic temperature compensation and ElectRode automatic identification function, and realizes convenient operation and accurate measurement.

$ 1280.00

TDS value 7447ppm, capacity 480mL, PTFE bottle Encasement, versatility, suitable for daily solubility total solid calibrate, to ensure measurement accuracy.

$ 106.00

Measurement range 0.00-10 ppt, accuracy +/- 2% F.S., automatic temperature compensation and two-pole Graphite electRode design ensure fast Response and accurate measurement for harsh environments.

$ 209.00

Provides 71.8 ppm TDS value, 480mL capacity, PTFE bottle Encasement, suitable for total dissolved solids calibrating, ensuring measurement accuracy.

$ 106.00

Double line large screen display and two key operation, automatic single point recognition calibrated, built-in temperature sensor, Measurement range 0-20mS/cm, IP67 waterproof grade, suitable for harsh environments.

$ 306.00

TDS value 744.7ppm, capacity 480mL, using PTFE bottle Encasement, suitable for daily soluble total solids calibrated.

$ 106.00

Reduce Polarization effect with built-in Graphite electRode, Fast Response; Measurement range 0.00-6 mS/cm, accuracy +/- 2% F.S.; Automatic temperature compensation and single point recognition calibrate, easy to operate.

$ 227.00

Articles

The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Usage of Paint Film Solvent Rub Tester in Rapid Detection of Curing Degree
The paint film solvent resistance tester rapidly evaluates the degree of paint film curing by simulating solvent wiping. Its principle is that a fully cured paint film has a high cross-linking density, enabling it to resist solvent dissolution.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Selection of Coating Thickness Measurement Methods: Coulometry vs. Dissolution in Electrolytic Thickness Gauges.
This article compares two techniques in electrolytic thickness gauges: the coulometric method and the dissolution method. The coulometric method measures coating thickness through electrochemical dissolution, making it suitable for single-layer metal coatings with simple operation and high accuracy. The dissolution method, on the other hand, measures thickness via chemical dissolution, making it more appropriate for multilayer or complex coatings.