Ink particle size analyzer

The ink particle size analyzer measures the particle size distribution in ink through optical scattering. Its purpose is to monitor the uniformity of ink dispersion, and it is applied in pre-printing quality control to prevent spots or screen clogging in printed materials.
Selection
When selecting, consider that the measurement range should cover common ink particle sizes, employ laser diffraction technology to ensure accuracy, and require a user-friendly operation interface. Match the sample handling capacity, such as an automatic circulation system. Refer to industry standards to verify instrument repeatability, and evaluate maintenance costs and supplier technical support.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.

$ 5237.00

The image method is used to analyze the particle morphology and particle size, the test range is 1~ 3500 μ m, the system magnification is 4000 times, the automatic segmentation success rate exceeds 93%, and paraMeters such as length-diaMeter ratio and sphericity can be counted.

$ 5366.00

100L/min Sampling flow rate and six particle size channel detection, equipped with long life laser Illuminant and imported air pump, support Touchscreen operation and USB data export function.

$ 10578.00

Using 50L/min Sampling flow rate and six particle size channel synchronous detection, equipped with semiconductor laser Illuminant and Touchscreen control, built-in thermal printer supports real-time data output, Continuous Operating Time up to 5 hours.

$ 8461.00

Test range 0.5~ 3000μm, Maximum magnification 4000 times, can analyze the number of particles, area, circumference, diaMeter, aspect ratio and other distribution data, support a variety of formats of test report output.

$ 6205.00

Using light scattering principle to detect 0.3-10 μ m particle size, Sampling flow rate 28.3L/min, built-in lithium battery supports 6 hours of work, can directly save data to U disk, equipped with thermal printer for on-site output.

$ 3922.00

With six-channel particle size detection and 2.83L/min Sampling flow rate, using laser Illuminant life of over 30,000 hours, support UCL calculation and Built-in Printer, AC-DC dual-use can work continuously for more than 6 hours.

$ 848.00

With 6-channel synchronous detection capability, maximum sampling concentration of 35000 pcs/L, using semiconductor laser Illuminant life of 10 years, built-in battery life of more than 5 hours and support data export printing.

$ 1501.00

With six-channel particle size detection capability, Sampling flow rate 2.83L/min, using long-life laser Illuminant to ensure Stability, built-in thermal printer and support AC and DC power supply, can work continuously for more than 6 hours.

$ 1171.00

Using 15.5cm/min ink wiping speed, equipped with 0.1mm ink coating platen, the test process is precisely controlled by 4.3 inch Touchscreen, which can accurately determine the absorption capacity of the material to the inks vehicle.

$ 2784.00

Explosion-proof enclosure design ensures stable operation in harsh environments, can simultaneously monitor multiple particle size dust concentration without changing the cutter, Measurement range 0.01-100 mg/m ³, built-in protective gas curtain to prevent Optical inspection system contamination.

$ 5043.00

Image segmentation technology is used to process overlapping dust and maintain particle prototype; Measurement range is 0.1~ 3000μm, repeatability error ≤ +/- 1%; support custom particle size classification and various image processing methods.

$ 9998.00

Automatic ink running stability, ink time and speed can be set, printing pressure 0~ 2mm adjustable, provide low, medium and high three printing speed, each time can be proofed 4 colors to facilitate Color contrast.

$ 3430.00

The ink wiping speed of the instrument is 15.5 +/- 25px/min, the ink absorption time is 120 +/- 5s, and the 4.3 color Touchscreen control can accurately evaluate the acceptance of inks and the absorption capacity of the vehicle.

$ 4342.00

With six particle size channel detection capability, sampling capacity of 2.83L/min, built-in lithium battery supports 6 hours of continuous operation, using semiconductor laser Illuminant and color Touchscreen design.

$ 2510.00

Articles

How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Blue-style grinder achieves efficient grinding of ink fineness.
The basket mill is a type of wet grinding equipment used in fine chemical fields such as ink production. It utilizes a high-speed rotating impeller to drive grinding media, generating shear and impact forces on the slurry, thereby dispersing pigment particles and reducing their fineness.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
An article tells you how to choose a fineness gauge.
This article introduces how to select and use a grind gauge. It is a tool for measuring particle size in coatings and inks. When selecting one, the first step is to choose the appropriate range based on the estimated fineness of the sample (commonly 0-50 µm or 0-100 µm).