VOC Fixed Gas Monitor

The VOC fixed gas detector uses sensors to measure the concentration of volatile organic compounds in the air and converts chemical signals into electrical signals for output. It is used for leak monitoring and concentration warnings in places such as chemical plants and printing workshops to ensure a safe working environment.
Selection
When selecting, consider matching the type and range of gases to be detected, determine the explosion-proof level and protection standards based on environmental characteristics, choose wired or wireless transmission methods according to on-site wiring conditions, and regularly calibrate to maintain sensor lifespan.

Terms

Standards

Instruments

Pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.01ppm, support 1-5 Sensor expansion, IP65 Protection Rating, suitable for harsh environments.

$ 754.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote monitoring and linkage control.

$ 332.00

Using 32-bit microprocessor and 24-bit ADC chip, equipped with 2.4-inch high definition display, supports 1-6 Sensor configurations, with 4-20mA, RS485 and other signal output, Protection Rating up to IP65, Response Time ≤ 20 seconds.

$ 545.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds; with flameproof structure and a variety of signal output, support remote monitoring and customized range, through a number of international safety certifications.

$ 332.00

Adopt pre-treatment technology, adapt to high temperature, humidity and dust environment, equipped with 7-inch Touchscreen real-time display concentration Linear dispersion, detection error ≤ +/- 3% F.S, support 4-20mA and RS485 output, can realize automatic drainage and zero emission cycle function.

$ 1493.00

Adopt ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³; equipped with independent variable frequency wind speed adjustment device, the wind speed range is 0.1-1 m/s; Modular design is easy to maintain, and the integrated gas supply purification system is easy to operate.

$ 35348.00

Using ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³, equipped with independent variable frequency wind speed adjustment device, Modular design is easy to maintain, and the operating power is as low as 1.2kw.

$ 25602.00

Equipped with 2.4-inch high definition color screen, supports 1-6 Sensor expansion, with 4-20mA and RS485 output, Response Time ≤ 20 seconds, Protection Rating IP65, suitable for harsh industrial environments.

$ 583.00

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Pump-suction sampling and a variety of detection principles, Response Time ≤ 20 seconds, accuracy ≤ +/- 3%, built-in 3800mAh battery, support 120,000 sets of Data storage and Temperature Humidity detection.

$ 527.00

Electrochemical sensor, Response Time less than 30 seconds, Measurement accuracy +/- 3% FS, 4-20mA standard signal output and passive relay control port, suitable for a variety of Gas detection needs.

$ 267.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure, support 4-20mA and RS485 output, suitable for a variety of Gas detection.

$ 251.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure, support 4-20mA and RS485 output, suitable for a variety of Gas detection.

$ 193.00

Pump-suction sampling and PID Photoion Sensor technology, Response Time ≤ 20 seconds, resolution of 0.001 ppm, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 2557.00

It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.

$ 189.00

Articles

Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Circle Method Adhesion Tester for Evaluating the Adhesion of Paint Coatings by the Circular Rolling Line Method
The rolling circle method is a technique for testing the adhesion of paint coatings using a circle-drawing instrument. The instrument employs a fixed-load stylus to draw a continuous circular trace on the coating at a constant speed, and the adhesion level is assessed based on the peeling condition of the scratch.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Rotational Viscometer vs. Stormer Viscometer: How to Choose the Right Instrument Based on Coating Type
The rotational viscometer measures viscosity by detecting rotor torque and can analyze rheological properties at different shear rates, making it suitable for research and precise measurements. The Stormer viscometer uses the load at a fixed rotational speed to determine the KU value, simulating construction conditions, and is commonly used for rapid on-site evaluation of coating application performance.