Circulating Water Channel

The circulating water tank drives liquid flow within a closed pipeline through a pump, forming a stable circulating water flow. It is used to simulate fluid environments, test material erosion resistance, heat exchange efficiency, or particle suspension states. It is commonly employed in ship coating tests, thermal instrument calibration, and chemical process simulations.
Selection
Select corrosion-resistant materials based on the testing medium, match pump power according to flow rate requirements, and consider the compatibility of tank dimensions with the experimental space. Pay attention to temperature control accuracy and fluid stability indicators, and check the compatibility of sealing components. Reserve sampling ports and sensor interfaces to facilitate data collection.

Terms

Standards

Instruments

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

Using circulating water as the working fluid, the maximum Vacuum Level is -0.098Mpa, the pumping rate is 80L/min, the special fluid muffler reduces the noise, the double tap design can be used alone or in combination, and the ABS engineering plastic shell is resistant to corrosion.

$ 267.00

With +/- 0.1 ℃ temperature fluctuation and 0.1 ℃ resolution, built-in circulating water pump supports internal and external circulation, integrated over-temperature alarm and 9999 minutes timing function to ensure stable and efficient experiment.

$ 1434.00

Colorimetric integrated tube design, no need to transfer liquid, support more than 10 measurements to take the average value, measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, built-in two COD detection methods, can expand a variety of water quality paraMeter detection.

$ 2526.00

Using 32-bit high-speed MCU and 24-bit AD chip, Measurement accuracy 0.2 ℃ + 2 word, support up to 64 channel expansion and 350V channel isolation, with multi-interface display and U disk export function.

$ 1380.00

Using circulating water as the working fluid, the jet generates negative pressure, the pumping rate is 80L/min, the maximum Vacuum Level is -0.098Mpa, the double tap design can be used alone or in combination, and the special fluid muffler reduces the noise.

$ 315.00

Temperature Fluctuation +/- 0.1 ℃, Temperature range + 5~ 99 ℃, with Sensor fault alarm and over-temperature protection function, built-in circulating water pump supports internal and external thermostatic water flow output.

$ 1161.00

Using 32-bit high-speed MCU and 24-bit AD chip, the inter-channel withstand voltage AC/DC 350V, the built-in 8G memory can record continuously for 97 days, and supports multi-channel independent error correction and alarm functions.

$ 1017.00

Using 24-bit high-speed AD measurement chip, accuracy of 0.2 ℃ + 2 words, support 40-channel wireless expansion and 0.1 second fast recording, built-in 8G memory can store 12 million sets of data, channel isolation voltage up to 350V.

$ 1122.00

Equipped with a 5-inch 854 × 480 high definition touch screen, supports 64-channel independent temperature acquisition, uses 32-bit MCU and 24-bit AD chip to ensure 0.2 ° C accuracy, has 130,000 data storage and 97 days of continuous recording ability, channel voltage 350V anti-interference.

$ 1315.00

Temperature range -30 to 100 ℃, Tank volume 4.5 liters, imported Compressor and circulating pump to ensure stable operation, support multi-stage programmable control and internal and external circulation mode.

$ 1450.00

Temperature range -50~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, support multi-stage programming and data processing interface, with over-temperature alarm and liquid level protection function.

$ 3335.00

Temperature range -50~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, support multi-stage programming and data processing interface, with over-temperature alarm and liquid level protection function.

$ 3038.00

Temperature range -10~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, low noise, fast cooling, with over-temperature alarm and liquid level protection function, support multi-stage programming and data processing interface.

$ 1756.00

Temperature range -40~ 100 ℃, accuracy up to +/- 0.02 ℃, support 7 groups of 63 steps programmable settings, circulating pump Flow rate 8L/min, with over-temperature alarm and liquid level protection to ensure safe and reliable experiments.

$ 2347.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.