Adjustable Light Incubator

The adjustable light chamber simulates various lighting conditions using artificial light sources, controlling light intensity, wavelength, and duration. It is used to test the weather resistance, color stability, and aging behavior of materials under light exposure, commonly applied in light-aging experiments for coatings, plastics, and textiles.
Selection
When selecting an adjustable light incubator, it is essential to clarify the required light source type, spectral range, adjustable light intensity range, and uniformity for the experiment. Consider whether the chamber size matches the sample, the ease of operation of the control system, and data recording functions. Pay attention to the control capabilities of environmental factors such as temperature and humidity to ensure compliance with testing standard requirements.

Terms

Standards

Instruments

With six-level adjustable light and 0.1 ℃ Temperature resolution, it can simulate the change of day and night temperature and Humidity, and supports 30 sets of program settings to ensure the safe and stable operation of the experiment.

$ 1845.00

With five adjustable light and 10~ 65 ℃ Temperature range, using equilibrating refrigeration and air circulation technology to ensure uniform temperature, built-in intelligent humidification system supports automatic replenishment of external water Tank.

$ 1400.00

150L volume design, Temperature range 4~ 50 ℃, Illumrination degree 0~ 12000LX, six adjustable light, can simulate day and night temperature Humidity changes, support 30 sets of program settings, independent temperature limit alarm system to ensure safe operation.

$ 2042.00

With five-stage adjustable light and a wide Temperature range of 10~ 65 ℃, ALLCOLD equilibrate refrigeration and ALLFLOW air circulation are used to ensure uniform and stable temperature. Support multi-stage programming and RS485 connection for long-term experimental monitoring.

$ 2826.00

Adopting mirror stainless steel liner and unique air duct circulation to ensure Temperature Uniformity +/- 1.5 ℃, 24-stage program can be set to simulate day and night changes, support 0~ 12000LX four-level adjustable light, safe temperature limit alarm.

$ 1369.00

Temperature range of 0~ 50 ℃ and light intensity of 0~ 12000LX, support five-level light regulation and 99-segment program control, using PID intelligent temperature control system and pressure equilibrating refrigeration technology to ensure long-term continuous and stable operation.

$ 2612.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

With 0~ 15000LX four-level adjustable illumination, support 24-stage program settings, 1-99 hours each. Unique air duct system ensures uniform temperature, mirror stainless steel liner for easy cleaning, temperature limit alarm to ensure safety.

$ 1451.00

With 0~ 50 ℃ Temperature range and 0~ 18000LX Illumrination degree, using PID control technology to ensure stable temperature and humidity, support five-level light adjustment and power-off memory function.

$ 2831.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Temperature range 0~ 50 ℃ and Temperature Fluctuation +/- 1.0 ℃, five-level adjustable illumination 0~ 12000LX, support over-temperature alarm and power-off memory function to ensure long-term continuous operation.

$ 2281.00

Adopt five-stage adjustable lighting system, Illumrination degree 0~ 6000LX, Temperature range 10~ 65 ℃. Equipped with ALLCOLD ™ equilibrate refrigeration and ALLFLOW ™ air circulation to ensure uniform and stable temperature and support continuous operation.

$ 3412.00

Imported Compressor to achieve high efficiency and low energy consumption operation, equipped with six-stage adjustable lighting system, Temperature range 4~ 50 ℃, mirror stainless steel liner for easy cleaning, support 30 sets of program settings and independent temperature limit alarm.

$ 2052.00

Adopt ALLCOLD equilibrate refrigeration technology, equipped with automatic defrosting function, temperature control accuracy of +/- 1 ℃; five-stage adjustable lighting system up to 15000LX, support multi-stage programming control, to meet the needs of long-term continuous experiments.

$ 3288.00

With 0.1 ℃ temperature resolution and +/- 1 ℃ uniformity, it supports day and night independent temperature and light settings, and the liner is made of stainless steel to ensure long-term stable operation.

$ 2182.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.