Digital Illuminated Full-Temperature Oscillating Incubator

The digital display light-incubated full-temperature oscillation incubator maintains a constant temperature inside the chamber through its temperature control system, simulates daylight conditions with its lighting device, and ensures uniform mixing of samples via the oscillation platform. It is used for experiments such as microbial culture and seed germination, and is commonly employed in the fields of biology and agriculture.
Selection
When selecting, consider the temperature range and fluctuation, adjustable light intensity levels, oscillation frequency and amplitude parameters, corrosion resistance of the chamber material, clarity of the operation interface, matching sample capacity to experimental needs, operational stability, and maintenance convenience.

Terms

Standards

Instruments

Adopt Full Digital Control Frequency AC Motor, Speed accuracy +/- 0.5%, Effective Travel 850mm, High Accuracy Double Roller Screw and Guide Column, Support Tensile, Compression, Tension and other test modes.

$ 3583.00

Temperature control accuracy of 0.1 ℃, Temperature Fluctuation +/- 0.5 ℃, with oxygen holes to ensure that the foster environment is fully supplied with oxygen, spring bottle rack to support a variety of comparative experiments, stepless speed range start to 260rpm.

$ 1664.00

With full light 10~ 50 ℃ and no light 5~ 50 ℃ Temperature range, Temperature Uniformity +/- 2 ℃, Illumrination degree ≥ 2500lx, suitable for a variety of experimental needs, stable and reliable performance.

$ 975.00

Adopt full digital control AC motor, speed accuracy +/- 0.5%, effective force range 1~ 100% FS, strong structural rigidity, support a variety of test modes such as tensile, compressive, tensile, etc., easy to operate, stable and reliable.

$ 4066.00

Adopt full digital control AC motor, speed accuracy +/- 0.5%; High Accuracy double roller screw structure, force measurement range 1-100% F.S; Travel, force protection and emergency stop device, support tension and pressure test.

$ 3623.00

Full digital control AC motor, speed accuracy +/- 0.5%, maximum range 5000N, high structural rigidity, support stepless speed regulation and high temperature testing to ensure stability and reliability.

$ 6367.00

High Accuracy all-digital speed control system and precision gear reducer are used to drive the precision lead screw to achieve wide range speed adjustment of 1~ 500mm/min. Precision test force is less than +/- 1%, low noise and smooth operation.

$ 1074.00

Temperature range 5~ 50 ℃, temperature accuracy +/- 0.5 ℃, with forced air circulation system to make the temperature distribution uniform, support Oscillation Frequency start to 280rpm and timing function, built-in lighting for easy observation of the experimental process.

$ 1763.00

Compliant with ISO 8502-3 standard, equipped with illuminated magnifying glass and dust comparison display panel, can accurately assess the size and distribution of surface dust, support pass test and long-term recording.

$ 367.00

With refrigeration and heating two-way temperature regulation function, Temperature range 5~ 50 ℃, volume 250L, suitable for thermostatic fostering and tissue cell preservation, support scientific research needs.

$ 835.00

Using polyurethane foam insulation, strong anti-interference ability; working Chamber with air duct, uniform temperature distribution; inner wall embossed Aluminum Panel or stainless steel material, corrosion resistance; Temperature range 5~ 50 ℃, Temperature Uniformity +/- 0.5 ℃.

$ 680.00

With heating and cooling two-way temperature control system, Temperature range 5~ 50 ℃, Temperature Uniformity +/- 0.5 ℃, the inner wall is made of embossed Aluminum Panel or stainless steel, good corrosion resistance performance.

$ 837.00

With refrigeration and heating bidirectional temperature control system, Temperature range 5~ 50 ℃, accuracy +/- 0.5 ℃, Oscillation Frequency up to 200rpm, stainless steel cavity and polyurethane insulation material, corrosion resistance and anti-interference.

$ 1027.00

With refrigeration and heating bidirectional temperature regulation function, Temperature range 5~ 50 ℃, volume 150L, suitable for thermostatic fostering and tissue cell preservation.

$ 740.00

Temperature control accuracy +/- 0.2 ℃, Temperature Uniformity ≤ +/- 0.3 ℃, DC brushless motor drive maintenance-free, with power-off automatic recovery and 0-100 hours timing function, support a variety of module replacement.

$ 908.00

Articles

Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.