Settling Tube Grain Size Analyzer

The sedimentation tube particle size analyzer measures particle size distribution based on the relationship between the settling velocity of particles in a liquid and their particle size. Particles settle under the influence of gravity, and their size is calculated according to Stokes' law. It is used for particle size analysis of powders and suspensions in industries such as coatings and inks.
Selection
When selecting a sedimentation tube particle size analyzer, it is essential to consider that the measurement range covers the particle size of the samples, the sedimentation medium is compatible with the samples, temperature control is stable to ensure measurement accuracy, the operation is simple to meet daily testing needs, and maintenance is convenient to reduce usage costs.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

Measurement range 8~ 20%, Accuracy of +/- 0.6%, suitable for rice, rice, wheat, corn four kinds of grain, Operating temperature 0~ 50 ℃.

$ 164.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 3-80%, the accuracy is +/- 0.5%, 25 kinds of special gears for grain, the integrated design is easy to carry, and the Response Time is only 1 second.

$ 165.00

Sensor and host split design, measurement range 3-80%, accuracy +/- 0.5%, support 37 kinds of grain type measurement, with temperature and humidity compensation function, Response Time is only 1 second, Portable structure is convenient for on-site rapid detection.

$ 186.00

U-shaped tube design, viscosity measurement range of 0.9~ 3cSt, based on the liquid flow time in capillary tubing is proportional to the viscosity principle, suitable for a variety of liquid sample determination.

$ 461.00

U-shaped tube design, viscosity measurement range of 200-1000cSt, based on the principle of capillary tubing can accurately determine the kinematic viscosity of liquids at constant temperature.

$ 461.00

U-shaped tube design, viscosity measurement range of 2000 to 10000cSt, based on the principle of liquid flow time in capillary tubing is proportional to kinematic viscosity to ensure accurate measurement.

$ 461.00

U-shaped tube design, viscosity measurement range of 60-300cSt, based on the principle of capillary tubing to achieve accurate measurement of liquid kinematic viscosity and outflow time.

$ 461.00

U-shaped tube design, viscosity measurement range of 6-30cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity, suitable for accurate measurement of various liquid samples.

$ 461.00

Conductivity Detector principle and temperature and humidity compensation technology, measurement accuracy of +/- 0.5%, Response Time of 1 second, integrated design supports on-site rapid detection, suitable for a variety of grain moisture measurement.

$ 112.00

U-tube countercurrent design, viscosity measurement range 6000-30000cSt, based on the principle of capillary tubing by measuring the liquid outflow time to accurately calculate the kinematic viscosity, suitable for high viscosity liquid analysis.

$ 461.00

U-tube countercurrent design, viscosity measurement range of 2~ 10cSt, based on the principle of capillary tubing by measuring the liquid outflow time accurate calculation of kinematic viscosity, suitable for a variety of liquid samples.

$ 461.00

Measurement principle using resistance method, accuracy of 0.1%, support a variety of grain Measurement range, with voice reminder and automatic shutdown function, portable design weighs only 254g.

$ 90.00

U-shaped tube structure, viscosity measurement range of 20-100cSt, based on the liquid flow time in capillary tubing is proportional to the viscosity principle, to ensure accurate and reliable measurement.

$ 461.00

U-tube countercurrent design, according to BS/IP/RF standard, viscosity measurement range covering 600 to 3000cSt, based on the principle of capillary method to ensure that the liquid flow time in the upright tube is proportional to the kinematic viscosity.

$ 461.00

Articles

Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Sieve Residue Analyzer and Sieve Analysis for Determining Pigment Particle Size Distribution
This article introduces how the sieve residue analyzer measures the particle size distribution of pigments through mechanical sieving.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.