Magnetic Paint Film Thickness Gauge

The magnetic paint film thickness gauge measures the change in magnetic flux between the probe and the ferrous base material through the principle of magnetic induction, converting it into the thickness of the paint film. It is used for detecting the thickness of coatings on ferrous substrates and is suitable for quality control in industries such as automotive and shipbuilding.
Selection
When selecting, consider the substrate type, coating thickness range, measurement accuracy, and probe size. For ferrous materials, use the magnetic principle, check whether the instrument's range covers the coating to be measured, ensure the accuracy meets process requirements, and ensure the probe is compatible with the workpiece shape.

Terms

Standards

Instruments

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.

$ 359.00

Using magnetic Induction and eddy Current dual principle, measurement range 0-2000μm, accuracy +/- 3%, equipped with ruby probe wear and corrosion resistance, support automatic identification of iron-based and non-iron-based materials, no need to calibrate easy to operate.

$ 175.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measuring methods of magnetic Induction and eddy Current, covering 0-1500 μm range, resolution up to 0.1 μm, support continuous and single Measurement mode, statistical function and 500 sets of data storage, suitable for different curvature radii and substrate Film thickness scenes.

$ 243.00

Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.

$ 219.00

Using magnetic Induction principle to achieve 0-6000μm large-range measurement, the error is only +/- 3%. With continuous single double measurement mode, support four-point statistical function, large-capacity storage of 2000 sets of data, automatic identification of matrix material.

$ 323.00

Hardness and corrosion resistance, wet film thickness adjustment range 0-4500 μ m, magnetic suction design for quick replacement and cleaning, differential head accuracy of +/- 2 μ m to ensure film uniformity.

$ 393.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1500 μm, with temperature compensation function, support continuous fast and High Accuracy Measurement mode, can store 500 sets of data and automatically filtrate outliers.

$ 264.00

With paint penetration measurement ability, accurate measurement of wall thickness without removing coatings, thickness range 2.5~ 125mm, accuracy +/- 0.03mm, support multi-echo and single-echo mode switching, suitable for detection needs of different surface conditions.

$ 2739.00

Using the magnetic induction method, the measurement range is 0~2000 μm, with an error of ±5%, a resolution of 0.1 μm. It supports separate probes and low-voltage alerts, and is suitable for various types of coatings.

$ 243.00

The magnetic suction removable drawdown blade structure is easy to clean, the film thickness range is adjustable from 0 to 5000 μm, the drawdown blade accuracy is up to +/- 2 μm, and the hard aluminum oxide frame is lightweight, wear-resistant and corrosion-resistant.

$ 977.00

Adopt magnetic Induction principle measurement 0-10mm thickness range, resolution up to 0.1μm, Probe wear-resistant more than 500,000 times, suitable for -10-50 ℃ environment, error range +/- 3%, stable and fast test.

$ 369.00

Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.

$ 340.00

High-quality alloy steel scraper, Hardness and wear resistance and corrosion resistance, Film thickness adjustment range 0-4500 μ m, magnetic suction design for quick replacement and cleaning, differential head accuracy of +/- 2 μ m to ensure uniform and stable film.

$ 251.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.