Suspended Solids Meter

Suspended solids analyzers measure the content of insoluble solid particles in liquids through optical or gravimetric methods. The principle involves the scattering or absorption of light by particles as it passes through the sample, with the instrument detecting changes in light intensity to calculate concentration. Their role lies in monitoring water quality and controlling industrial processes. They are applied in wastewater treatment, drinking water testing, and industrial emission monitoring.
Selection
When selecting a suspended solids measuring instrument, consider the measurement range to match the sample concentration, such as optical methods for low concentrations and gravimetric methods for high concentrations. Confirm that the accuracy and repeatability meet standard requirements. Check the instrument's compatibility with sample types and its anti-interference capability. Evaluate the ease of operation and maintenance needs to ensure suitability for the practical application environment.

Instruments

The imported cold light source does not need to be preheated for 100,000 hours, the minimum display value is 0.001mg/L, supports standard measurement and continuous measurement modes, and the built-in large-capacity lithium battery realizes long standby, which can store 4000 sets of measurement data.

$ 806.00

Imported Illuminant and narrowband filter system, Optical inspection stability, high accuracy; measurement range 0-1000mg/L, repeability +/- 2% F.S; Large screen Chinese display, easy to operate without Reagent.

$ 574.00

Measurement range 0~ 2000 NTU, Accuracy +/- 2%, support TSS conversion and 200 data storage, password protection and continuous measurement function.

$ 724.00

Colorimetric integrated tube design is adopted, sample digestion and detection share a tube, no need to transfer liquid; support more than 10 measurements and automatically remove abnormal values to average, error ≤ +/- 5%; can expand the detection of COD, ammonia nitrogen and other paraMeters.

$ 3228.00

Accuracy up to 1mg/L, Measurement range 0-500mg/L, support AC and DC dual power supply and automatic shutdown function, Repeatability 3%, Linearity +/- (5% FS + 1 word) to ensure stable and reliable measurement.

$ 278.00

Colorimetric integrated tube design, supports more than 10 measurements to take the average value, measurement error ≤ +/- 5%, built-in 30,000 data storage and thermal printer, can expand the detection of ammonia nitrogen, total nitrogen and other paraMeters.

$ 2877.00

Measurement range 0-500mg/L, accuracy 1mg/L, Repeatability 3%, support AC and DC power supply and automatic shutdown, suitable for a variety of liquid suspended matter detection.

$ 300.00

TDS value 744.7ppm, capacity 480mL, using PTFE bottle Encasement, suitable for daily soluble total solids calibrated.

$ 104.00

Provides 71.8 ppm TDS value, 480mL capacity, PTFE bottle Encasement, suitable for total dissolved solids calibrating, ensuring measurement accuracy.

$ 104.00

Built-in Wine pH ElectRode with CPS technology, Measurement range 0.00~ 12.00pH, accuracy +/- 0.05pH@25 ° C. Compact design weighs only 46g, CR2032 battery provides 1000 hours of battery life, suitable for rapid on-site inspection.

$ 296.00

Colorimetric integrated tube operation, no liquid transfer; measurement error ≤ +/- 5%, Repeatability ≤ +/- %; Support Multi-ParaMeter detection and post expansion, built-in thermal printer and 30,000 data storage.

$ 4375.00

Using Electromagnetic Force Sensor to ensure data accuracy and Repeatability, density Measurement range 0~ 300g/cm ³, can measure solids and liquids, including floating materials, easy to operate without special training.

$ 622.00

Adopt digestion Colorimetric integrated tube design, no liquid transfer; support more than 10 measurements to take the average value, error ≤ +/- 5%; can store 30,000 data, compatible with 16mm and 25mm Colorimetric tubes.

$ 3387.00

Colorimetric integrated tube design, no need to transfer liquid, can be more than 10 times of measurement and remove the abnormal value to take the average, measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, built-in 30,000 data storage and thermal printer.

$ 2718.00

Colorimetric integrated tube design, sample digestion and result reading share a tube, no need to transfer liquid; more than 10 measurements of water samples and removal of abnormal values are averaged to reduce errors; built-in two COD detection methods, Measurement range 0-20000mg/L, detection limit as low as 2mg/L.

$ 3037.00