High Range Conductivity Meter

High-range conductivity meters measure the ability of a solution to conduct electric current through electrodes. They are suitable for detecting highly conductive media, such as concentrated acids, alkalis, and wastewater, and are used to quantify ion content in industrial water quality monitoring and chemical processes.
Selection
When selecting, consider that the measurement range covers the sample conductivity, the electrode material is corrosion-resistant, the temperature compensation matches the working conditions, the calibration function meets accuracy requirements, and the protection rating is suitable for the usage environment.

Terms

Standards

Instruments

Measurement range 0-2μS/cm with Mini-DIN 8 core connector for accurate detection of low conductivity solutions.

$ 199.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Measurement range of 0-200mS/cm, suitable for high Conductivity Detector liquids, equipped with 5 Meters low noise Shielding cable.

$ 140.00

Conductivity Detector ElectRode realizes multi-range measurement, range 0.0 to 199.9 mS/cm, single point calibrating is simple, automatic temperature compensation ensures accuracy, waterproof design is suitable for harsh environments.

$ 929.00

Support conductivity, TDS, salinity and resistivity Multi-ParaMeter measurement, conductivity range 0.000 μS/cm to 1000mS/cm, with intelligent end point determination and automatic temperature compensation function.

$ 741.00

With four conductivity Measurement range covering 0~ 199.9mS/cm, support 0.1, 1, 10 three ElectRode constants, manual temperature compensation range 0~ 50 ℃, can store 50 sets of data, easy operation and maintenance.

$ 135.00

Measurement range 0.00μS/cm~ 100mS/cm, error +/- 0.5% F. S, temperature compensation coefficient 2%, LED display is clear, Stability is high, suitable for accurate conductivity detection.

$ 215.00

Measurement range 0-2μS/cm, suitable for ultra-low conductivity medium, support temperature compensation and a variety of installation scenarios to ensure Data Reliability.

$ 224.00

Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.

$ 208.00

Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.

$ 99.00

With 0.00μS/cm~ 200mS/cm conductivity Measurement range, support seven-speed range automatic conversion and manual temperature compensation, anti-corrosion and waterproof design can adapt to harsh environments, integrated structure reliable and durable.

$ 269.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

Measurement accuracy of 0.5% and automatic temperature compensation, Conductivity Detector cell constant 0.1/1/10 optional and 500 data storage, suitable for a variety of liquid environment measurement.

$ 361.00

Using Platinum Sensor to ensure linear and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 20mS/cm, suitable for conventional liquid detection, Operating temperature 0~ 80 ℃.

$ 102.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Articles

Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Selection of wet film thickness gauge range and accuracy requirements for comb teeth spacing.
When selecting a wet film thickness gauges, the key considerations are the measurement range and the accuracy of the comb teeth spacing. The range should cover the coating thickness with a slight margin to avoid being too small for measurement or too large, which could reduce resolution.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Selection Recommendations for Carton Compression Strength Testing Machines
When selecting a cardboard compression strength tester, the first step is to examine the core parameters, such as ensuring the force range covers the testing requirements with some margin, the accuracy is typically no less than ±1%, and the testing speed complies with standard specifications.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Don't be fooled by the specs! The 3 key metrics to focus on when purchasing a tensile testing machine.
When purchasing a tensile testing machine, don’t just look at the parameter sheet. Focus on three core indicators: first, the accuracy and range of the force measurement system; second, the accuracy of displacement and deformation measurements; and third, the performance of the control and data acquisition system.
An article tells you how to choose a fineness gauge.
This article introduces how to select and use a grind gauge. It is a tool for measuring particle size in coatings and inks. When selecting one, the first step is to choose the appropriate range based on the estimated fineness of the sample (commonly 0-50 µm or 0-100 µm).