Low-temperature thermal paper

Low-temperature thermal paper develops color when heated between 40-80℃. Its coating contains colorless dyes and developers, with text and patterns formed by heating from a thermal print head. It is used for ambient temperature recording applications such as supermarket receipts and logistics labels.
Selection
When selecting, pay attention to the whiteness and smoothness of the paper, check the shelf life, and test print clarity. Match paper thickness according to the printer model, choose moisture-resistant types for humid environments, and avoid such papers for long-term storage needs.

Terms

Standards

Instruments

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

Using triple-channel thermal insulation structure, the damper switching time is completed within 10 seconds, and the temperature recovery time is within 5 minutes. With 96 test specification settings, the maximum Impact time is 9999 minutes, meeting the needs of high and low temperature rapid change testing.

$ 27829.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.

$ 16840.00

Adopting triple-channel thermal insulation structure, the throttle switching time is completed within 10 seconds, and the temperature recovery time is completed within 5 minutes. With 96 test specification settings, the Impact time can reach 9999 minutes, and the cycle period is 9999 times, meeting the needs of High Accuracy Temperature Control.

$ 16372.00

Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time up to 9999 minutes, with 96 test specifications independently set and automatic defrosting function.

$ 22019.00

Using irreversible discoloration technology to accurately record the highest temperature experienced, 8-grid rectangular temperature points cover the range of 160 ° C to 199 ° C, with oil and water resistance and ISO 9001 standard, accuracy of +/- 1% range.

$ 92.00

Using irreversible discoloration technology, 8 temperature points accurate monitoring, Precision up to +/- 1 ℃, with oil and water resistance, in line with ISO 9001 standard, size 51 * 18mm easy to paste use.

$ 89.00

With two-box mobile Impact structure, the temperature recovery time is less than 5 minutes, and the conversion time is only 10 seconds. Equipped with rigid polyurethane foam insulation material, it has ultra-low temperature thermal conductivity and waterproof performance, and supports programmed temperature control.

$ 14564.00

Dynamic Impact is achieved with a two-box mobile structure, with a hot and cold conversion time of 10 seconds and a temperature recovery time of 5 minutes. It is equipped with rigid polyurethane foam insulation material, with ultra-low temperature thermal conductivity and multiple safety protection devices.

$ 14564.00

Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time can reach 9999 minutes. With 96 test specification settings and P.I.D automatic calculation control to ensure Test accuracy.

$ 20228.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Measurement range 10~ 16000mN, resolution 0.1mN, pneumatic fixture to ensure stable clamping, thermal printer real-time output test data, suitable for a variety of sheet material Tear strength detection.

$ 2066.00