Adopt 4mm small diaMeter design, accuracy of 0.1, 1.5 seconds fast measurement, support Automatic calibration and APP Data storage, equipped with ceramic whiteboard luminance value greater than 90.
Brass material Benchtop design, flow hole diaMeter 4mm, volume 100ml, in line with GB/T1723 standard, suitable for viscosity below 150s Coating detection, correction factor 0.97~ 1.03.
Spreader accuracy +/- 0.003mm, Spreader thickness range 0.001~ 10mm adjustable, with Vacuum chuck and heating function, support bar and drawdown blade two coating methods to ensure Spreader uniformity and repRoducibility.
Automatic calibration without preheating zero adjustment, 1.5 seconds fast measurement, accuracy of 0.1, equipped with 4mm small diaMeter measurement head, support connecting mobile app and computer software to achieve Data storage and report export.
Using Blade Coating method, Spreader accuracy of +/- 10μm, Spreader thickness range of 0~ 5000μm, support stepless speed control and Touchscreen operation, effectively improve film conformity and experimental efficiency.
Adopt imported accessories to ensure Stability, Blade Coating accuracy up to +/- 0.003mm, coating speed 5~ 200mm/s adjustable, effective coating area 400 * 400mm, improve film repRoducibility by controlling speed and pressure.
The 45 ° fixed angle design ensures precise application of 1000g constant pressure, coating marks are evaluated by 13 different Hardness pencil systems, and the four-link mechanism ensures test Stability.
Using imported accessories, Blade Coating accuracy of +/- 0.003mm, coating speed 5~ 200mm/s adjustable, through the control of speed and stable pressure to ensure uniform Spreader, improve repRoducibility.
Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.
Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.
Spreader accuracy of +/- 0.001mm, coating speed 2~ 180mm/s stepless speed, removable drawdown blade easy to clean, heating Temperature Uniformity +/- 3 ℃, to ensure that the Spreader process is stable and efficient.
Measurement range 0~ 2.5mg/L, resolution 0.01mg/L, Repeatability 1%, small size and easy to carry, reduce the use of personnel requirements, to provide reliable detection results.
Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.
Measurement range 320~ 685cst, flow hole diaMeter 6mm, Benchtop design with bracket, ISO2431 standard, suitable for viscosity measurement.
Bluetooth ElectRode 10m wireless transmission, automatically identify ElectRode type and store calibrated data, equipped with 5.5-inch large screen and 12.7mm ultra-thin body, support 1000 groups Data storage and automatic temperature compensation.