Dyeing and Finishing Color Measurement Instrument

The dyeing color measuring instrument calculates color values by irradiating the sample and measuring the spectral data of the reflected light. It is used for color detection and comparison after textile dyeing, assisting in color quality control during production.
Selection
When selecting, consider matching the measurement aperture to the sample size, compatibility with industry-standard color difference formulas, and an instrument-to-instrument variation of less than 0.4 ΔE. It must include temperature compensation functionality, and the accompanying color management software should be capable of exporting reports in standard formats.

Terms

Instruments

Adopting D/8 geometrical optics structure, supports Φ 8/4mm dual aperture switching, simultaneous measurement of SCI and SCE, Light spectrum reflectance Repeatability Standard Deviation within 0.08% to ensure accurate and reliable Color data.

$ 4882.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

With 45 °/0 ° illumination and D65 Measurement light source, viewing angle of 10 °, support for multiple Color model conversion, weight of only 45g for portability, quality control and complementary color suggestions.

$ 380.00

With four Illuminant automatic switching function, display the use time of each Illuminant, no need to warm up without flashing, Color temperature range covers 2700K to 6500K, low energy consumption without heating, support Metamerism detection.

$ 354.00

With six Illuminant automatic switching function, no need to warm up without flashing, low energy consumption without heating, display the use time of each Illuminant, support Metamerism detection, Color temperature coverage 2700K to 6500K

$ 369.00

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

With five Illuminant system, Color temperature coverage 2700K to 6500K, no need to warm up without flashing, automatic switching Illuminant and display the use time, low energy consumption without heating, support Metamerism function.

$ 403.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab within 0.1, support cloud database and popular color search, portable design battery life up to thousands of measurements.

$ 441.00

Equipped with eight Illuminants and three measurement diaMeters, the repeability accuracy reaches 0.05, supports a variety of Color difference formulas and display modes, built-in whiteboard automatic correction, suitable for irregular surface and small area measurement.

$ 1687.00

With 4mm measurement diaMeter and vertical structure, short-term Repeatability accuracy Delta E ≤ 0.03, built-in whiteboard paraMeters do not need to be corrected, support light and cross dual positioning function, easy to operate and ready to use.

$ 393.00

Equipped with 50mm large measurement diameter, it can effectively deal with the Color measurement of uneven samples such as powder. Illuminant life of the instrument is up to 2 million times, the test port adopts full sealing design to prevent dust intrusion, and the Data storage capacity is up to 10,000 pieces.

$ 1187.00

Adopting D/8 geometrical optics structure, dual diaMeter Φ 8/4mm switching, simultaneous measurement of SCI/SCE, Repeatability Delta E * ab within 0.03, support powder, liquid and other sample measurement.

$ 5495.00

Equipped with eight Illuminant and eight Color difference formula, repeability accuracy of 0.05, support three display modes and 8mm general measurement aperture, built-in whiteboard automatic correction, suitable for a variety of materials Color measurement.

$ 1493.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

With Φ 4mm and Φ 8mm dual measurement caliber, Repeatability Delta E * ab < 0.06, can store 100 sets of master standards, Measurement time only 0.5 seconds, support sub-color difference display and Color bias analysis function.

$ 1009.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.