With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.
Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.
Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level protection and temperature runaway alarm functions.
The double Compressor and cascade refrigeration system are used to cool down quickly and have low noise; the overall foaming insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, integrated PID automatic temperature control and High Accuracy PT100 Sensor to ensure stability and accuracy.
The non-heat centrifugal circulating pump is used to ensure uniform insulation field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices such as low water level anti-dry burning and Compressor overcurrent protection, optional temperature control and external Sensor to enhance application flexibility.
Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection including low water level anti-dry burning and Compressor over-current protection to ensure the safety and stability of the experiment.
Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet diverse experimental needs.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, integrated PID automatic temperature control program and High Accuracy PT100 Sensor to ensure accurate and stable temperature control.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ° C. Integrated PID automatic temperature control program and High Accuracy PT100 Sensor ensure stability and accuracy.
Using non-fluorine environmental protection Compressor refrigeration, Temperature Uniformity up to +/- 0.05 ℃, equipped with 13L/min High Flow rate circulating pump, with low water level protection and temperature runaway alarm and other multiple safety functions.
Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming Tank body to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.
Imported Pt100 temperature sensor, Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, double Compressor cascade refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, integrated PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, resolution 0.0001 ℃, with multiple Safety protection devices.