Heat Shrinkage Tester

The heat shrinkage tester heats the sample to a set temperature and measures the dimensional change rate of the material under heated conditions. It is used to detect the shrinkage properties of plastic films, packaging materials, and other materials when exposed to heat, providing data support for adjustments in production processes.
Selection
When selecting, ensure the temperature range matches the material thickness, confirm that the clamping method is compatible with the sample size, check the temperature control accuracy and timing function, consider the compatibility of the data output format with existing systems, and determine the equipment durability requirements based on daily testing volume.

Standards

Instruments

Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.3 ℃, automatic timing function to ensure accurate and reliable testing, compact structure and easy handling.

$ 1663.00

Using oil Bath heating medium, Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.5 ℃, equipped with sample clamping grid to ensure temperature stability, suitable for various film thermal cissing rate tests.

$ 1510.00

The width of the groove is 2.5 times the maximum particle size of the coal sample, the slope of the groove is not less than 60 degrees, and it has multi-point shrinkage performance, which can effectively improve the sample representation and is suitable for the shrinkage of samples of different particle sizes.

$ 204.00

The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.

$ 1200.00

The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.

$ 1603.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.

$ 1764.00

Adopt digital P.I.D. temperature control, upper and lower heat seal independent temperature control, heat sealing temperature range RT +~ 300 ℃, heat sealing pressure 0.05~ 0.7MPa, support manual and foot pedal start mode, anti-burn safety design.

$ 1413.00

Adopt digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing pressure 0~ 0.7Mpa adjustable, double cylinder structure to ensure pressure equilibrating, heat sealing knife aluminum alloy material uniform heat conduction, support automatic and manual mode.

$ 1663.00

Digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing temperature up to 300 ℃; dual cylinder structure to ensure pressure equilibrating, heat cover temperature uniformity, support automatic and manual operation mode, improve test efficiency.

$ 1461.00

The heat sealing paraMeters are determined by hot pressing sealing method, the temperature control accuracy is +/- 0.1 ℃, the heat sealing temperature can reach 300 ℃, and the upper and lower heat sealing heads have independent temperature control and manual foot pedal dual start mode, which is safe and anti-scalding design.

$ 2110.00

The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.

$ 2494.00

Adopt double cylinder synchronous circuit and upper and lower heat seal independent temperature control, Heat seal Temperature range RT +~ 300 ℃, Temperature control accuracy +/- 1 ℃, support manual and pedal two start modes, heating head with protective cover to ensure safety.

$ 1300.00

Digital PID Temperature Control system, temperature control accuracy of +/- 0.2 ℃, the upper and lower heat head independent temperature control, double cylinder synchronous circuit to ensure pressure Balance, heat cover heating uniform, support manual and foot pedal dual operation mode.

$ 1656.00

Using transient planar heat source technology, the test time is adjustable from 5 to 160 seconds, the accuracy is +/- 3%, it supports nondestructive detection, no special sample preparation is required, and it is suitable for a variety of physical materials.

$ 5076.00