Rubber Density Balance

Rubber density balances are based on Archimedes' principle, calculating density by measuring the difference in mass of a sample in air and in water. They are used to detect the density uniformity of rubber products and find applications in quality control, material classification, and formulation verification.
Selection
When selecting, consider the matching of measurement accuracy with sample specifications, ensure the balance's weighing range covers the weight range of the samples to be measured, and that it is equipped with temperature compensation functionality. The operation interface should be simple and user-friendly, meeting the requirements of routine rubber testing environments.

Terms

Standards

Instruments

Density direct reading function eliminates cumbersome calculations, supports solid and liquid density measurement, with an accuracy of 0.001g/cm ³, equipped with RS232 interface and protective cover design to ensure stability testing.

$ 759.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, solid and liquid Density testing is supported, and the standard Density kit is easy to operate.

$ 841.00

Density direct reading function can avoid cumbersome calculation, equipped with all stainless steel Density bracket, weighing range 120g, accuracy 0.0001g, suitable for a variety of sample testing.

$ 1151.00

Density direct reading function eliminates cumbersome calculations, equipped with all stainless steel Density bracket, weighing range 200g, accuracy 0.001g, suitable for a variety of sample tests.

$ 546.00

High-precision Sensor for 0.01g Readability and 0.001g/cm ³ density accuracy, built-in multiple density references and rigorous calculation programs, supports solid liquid sample testing and directly displays density results.

$ 332.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and solid Density, volume and metal purity measurement are supported.

$ 716.00

Density direct reading accuracy of 0.01g, repeatability error +/- 0.01g, measurable solid and liquid density, all aluminum base design enhances weighing Stability.

$ 385.00

Density direct reading function eliminates the calculation step, can measure solid and liquid density, accuracy of 0.01g, Repeatability +/- 0.01g, all aluminum base design enhances weighing Stability.

$ 415.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and various measurement modes such as liquid Density are supported.

$ 587.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, supports liquid Density measurement and custom setting of Density upper and lower limits, and standard RS232 interface is convenient for data transmission.

$ 496.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 300g and readability up to 0.01g. Standard Density kit and RS232 interface facilitate data transmission.

$ 446.00

With 0.001g/cm ³ density accuracy and 0.01g readability, support solid liquid density test, built-in density reference table can directly display the results, configure the battery to realize mobile measurement.

$ 332.00

Density direct reading function eliminates calculation steps, can measure solid and liquid density, accuracy to three decimal places, equipped with display shield and all aluminum base, enhanced dust and Stability.

$ 680.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 220g readability 0.1mg, standard Density kit and RS232 interface support data export.

$ 932.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 120g readability 0.1mg, standard Density kit and various unit switching functions.

$ 887.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
Rotating Rubber Wheel Abrasion Tester for Determination of Coating Taber Abrasion Index
This article introduces the method for determining the Taber abrasion resistance index of coatings using a rotating rubber wheel abrasion tester.
Shore hardness tester measures the hardness of rubber sealing rings.
This article introduces the method of measuring the hardness of rubber sealing rings using a Shore durometer. The Shore durometer presses a needle into the rubber surface under spring force and converts the indentation depth into a hardness value, commonly using the A scale.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Rubber abrasion tester measures tire wear resistance.
The rubber abrasion tester evaluates wear resistance by simulating the friction between tires and road surfaces. It uses a grinding wheel to rub against rubber specimens under set conditions, measuring mass loss and converting it to volume loss to assess material performance.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Ozone Aging Test Chamber Evaluates Crack Resistance of Rubber
This article introduces how an ozone aging test chamber is used to evaluate the crack resistance of rubber. Ozone is a common factor that causes rubber aging. The test chamber simulates an ozone-containing environment, applies strain to rubber samples, and accelerates their aging process.
UV Aging Test Machine Evaluates Outdoor Lifespan of Rubber
This article introduces how ultraviolet aging test chambers assess the service life of rubber in outdoor environments. Rubber exposed outdoors is affected by factors such as sunlight, temperature, and humidity, leading to a gradual decline in its performance.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Insulation resistance tester measures rubber sealing gaskets.
This article introduces the method of using an insulation resistance tester to inspect rubber sealing gaskets.
Universal material testing machine measures the tensile modulus of rubber.
This article introduces how to measure the tensile modulus of rubber using a universal material testing machine. The tensile modulus is an important parameter that measures the ability of rubber to resist stretching under small deformations.
Selection of Wear Testing Machine: Types of Abrasion Wheels and Load Setting Methods
The test results of the wear testing machine primarily depend on the type of grinding wheel and the load setting. Grinding wheels include rubber wheels, abrasive wheels, wire wheels, and fiber wheels, among others. The selection should be matched based on the material characteristics and the actual wear scenario.
Shore durometer measures the elastic modulus of flexible resin.
This article explores how to use a Shore rubber hardness tester to measure the hardness of flexible resins and estimate their elastic modulus through theoretical models and empirical formulas.