Using high purity graphite material and fuzzy PID temperature control technology, temperature control accuracy +/- 0.1 ℃, with over-temperature alarm, temperature self-setting and thermostatic timing function, panel size 400 * 300mm.
Using 180 * 480mm size, with wire Rod or Film Applicator scraping ink, is conducive to the film flat and effective, improve film mass.
Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.
Adopting 500 * 700mm Dimensions, used with bar or Film Applicator, is conducive to the smooth and effective film, and improves the convenience of film operation.
Using high purity graphite PFA coating heating method, Temperature range RT +~ 400 ℃, monitoring accuracy +/- 0.5 ℃, digestion number of 20 holes, suitable for a variety of sample pretreatment, atomic absorption and other analytical instruments.
Graphite electRode to reduce Polarization effect, automatic temperature compensation to ensure accuracy, Measurement range EC 0-3999μS/cm, TDS 0-2000ppm, resolution up to 1μS/cm, suitable for harsh environments.
Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment needs.
Hardness stainless steel material, Hardness of 50~ 55HRC, film accuracy +/- 2μm, smooth surface to support a variety of Spreader requirements, can be used with Film Applicator to achieve automatic film operation.
Using a formed pRoduction process, the film Film thickness is as thin as 4.6μm, the accuracy is up to 0.1 micron, and the effective Spreader width is 30cm. It can be used with an automatic Film Applicator and has the advantage of continuous wire.
Spreader width 100mm, wet film thickness 40μm, wear resistant corrosion resistant alloy steel material, can be manually operated or with automatic Film Applicator to ensure coating conformity and Repeatability.
Double-sided design can be coated with two pre-order film thicknesses 90 and 150 μm, Spreader width 20mm, suitable for Automatic Film Applicator and Drying Time Recorder, in accordance with ASTM D 823 standard.
Temperature control accuracy of +/- 0.1 ℃, using fuzzy PID control technology, with over-temperature alarm and temperature self-tuning function, heating material is high purity graphite, panel size 600 * 400mm.
It can process 20 samples at the same time, the temperature control accuracy is +/- 1 ℃, and the corrosion resistance design and special oxidation resistance graphite block are used to ensure that the samples are heated evenly and have a long service life.
Formed to achieve 52.6 micron precision film, 304 stainless steel material provides high Abrasion Resistance, 50mm at both ends of the hand part without additional handle, can be directly matched with the experimental Film Applicator.
Temperature control accuracy +/- 0.1 ℃, Temperature range RT +~ 450 ℃, using fuzzy PID control to achieve fast stability and small overshoot, with over-temperature alarm and self-tuning function, heating material is high purity graphite.