Small Hot Air Circulating Oven

The small hot air circulation oven drives hot air to circulate inside the chamber through a fan, ensuring uniform heating of samples. It is used for drying and curing materials such as coatings and plastics in laboratories, and is suitable for rapid drying tests of small-batch samples.
Selection
When selecting, consider matching the sample characteristics with the temperature range, ensuring the chamber size meets placement requirements, the temperature control accuracy complies with experimental needs, the materials are corrosion-resistant and easy to clean, fan noise does not affect the environment, and energy consumption aligns with the spatial layout.

Terms

Standards

Instruments

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Adopt hot air circulation system to ensure Temperature uniformity, Temperature Fluctuation +/- 1 ℃, volume 30L, with over temperature deviation protection and timing function, can adjust the air inlet and exhaust volume.

$ 453.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, speed control fan can adjust the air volume to avoid blowing powder items, Temperature range RT + 10-300 ℃, studio volume 225L, equipped with independent temperature limit alarm system to ensure experimental safety.

$ 1474.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy of +/- 1.0 ℃, turbine centrifugal fan blade with the drum design, fan speed adjustable, studio mirror stainless steel easy to clean.

$ 1248.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Vertical double air duct vertical hot air circulation to ensure uniform temperature distribution, temperature control accuracy of +/- 1.0 ℃, equipped with large screen LCD display and independent temperature limit alarm system, support 1-9999 minutes timing function, effectively ensure the safe and stable operation of the experiment.

$ 3410.00

Temperature range RT + 10~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃, hot air circulation system to ensure uniform temperature in the studio, optional RS485 interface to record temperature and humidity paraMeters.

$ 483.00

Temperature range RT + 10~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃, using hot air circulation system to ensure uniform temperature in the studio, with independent temperature limit alarm and RS485 interface optional function.

$ 3170.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.5 ℃, hot air circulation system to ensure uniform temperature, with timing function and independent temperature limit alarm, support RS485 interface to record data.

$ 419.00

Vertical double air duct vertical hot air circulation design, high temperature uniformity, temperature control accuracy of +/- 1.0 ℃, studio volume 30L, equipped with turbine centrifugal fan blades and low noise blower, fan speed regulation, easy operation and maintenance.

$ 603.00

Vertical design with bottom drum and bottom heater, turbine centrifugal fan blade to achieve vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, studio volume 125L, PID microcomputer intelligent temperature control to ensure uniform and stable temperature.

$ 958.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.