Walk-in Temperature Test Room

The walk-in high and low temperature test chamber controls the internal temperature through refrigeration and heating systems to simulate the performance of products in extreme temperature environments. It is used to test the durability and performance changes of materials such as coatings and plastics under high or low temperature conditions.
Selection
When selecting a walk-in high and low temperature test chamber, it is essential to consider factors such as temperature range, uniformity, heating and cooling rates, size compatibility with sample requirements, energy consumption, and maintenance costs to ensure equipment reliability and long-term performance.

Terms

Standards

Instruments

Stainless steel studio corrosion resistance easy to clean, Temperature Uniformity +/- 5 ℃, equipped with over-temperature alarm and power protection, fan circulation to ensure uniform heat distribution, safe and reliable.

$ 5721.00

Using high-resolution video camera technology to replace the traditional Microscope, the temperature range is from room temperature to 350 ° C, and 4 samples can be processed simultaneously, compatible with powder and block sample measurement. Temperature resolution reaches 0.1 ° C.

$ 2010.00

Using 5MHZ Frequency and 10mm diaMeter Probe design, Measurement range 1.2-230 mm, the minimum pipe diaMeter can be measured Φ 20mm × 3mm, suitable for thickness detection in room temperature environment.

$ 109.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure stable and reliable operation.

$ 1837.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 922.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 1156.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature alarm function.

$ 5828.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 3586.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with large-screen LCD display and PID automatic temperature control to ensure stable and safe operation.

$ 942.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.

$ 2134.00

With two-way timing stirring function, Temperature range to 100 ℃, Speed range 0-2600rpm, support the maximum stirring amount of 3L, suitable for small volume sample precision and stable stirring.

$ 209.00

Heat collection heating method, heating speed and energy saving, Temperature range up to 300 ℃, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring.

$ 180.00

With a 5/10 station design and room temperature range, multiple samples can be tested simultaneously, and the adhesion and durability performance can be accurately evaluated through the suspension weight measurement of the displacement or complete disengagement time.

$ 427.00

Water and oil dual-use supports room temperature to 100 ° C, capacity 5L, Temperature Uniformity +/- 0.05 ° C, with domestic circulation system to avoid heat effects, external circulation to establish a second thermostatic field, Safety protection includes power failure and low water level alarm.

$ 435.00

With 25Khz and 45Khz dual-frequency conversion functions, it supports 1-600 minute timing and room temperature to 80 ° C temperature control. It is made of stainless steel to ensure durability and is suitable for a variety of cleaning needs.

$ 727.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.