Ultra-small portable design can be put into the pocket, equipped with protective rubber cover to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data, that is, there is no need to wait for the test; the use of special microcomputer control to eliminate external light interference, to ensure 0.1% resolution High Accuracy measurement.
Adopt stainless steel mirror liner and ultra-fine fiberglass insulation, Temperature Fluctuation ≤ +/- 0.5 ℃, uniformity ≤ +/- 2 ℃, equipped with large screen Touchscreen and automatic calculation function, improve temperature and humidity control accuracy and operation convenience.
Adopt stainless steel mirror liner and ultra-fine fiberglass insulation cotton, equipped with French Taikang fully enclosed Compressor, Temperature Fluctuation ≤ +/- 0.5 ℃, support 100 sets of program editing and RS-232/485 communication, improve test stability and convenience.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes a high degree of uniformity in the temperature field, with a temperature control accuracy of +/- 0.0050 ° C. It has multiple safety functions of low water level protection and Compressor.
Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.
Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.
Temperature range -20~ 150 ℃, Temperature Uniformity ≤ +/- 2.0 ℃, using stainless steel liner and ultra-fine Glass insulation cotton, with multi-layer conductive film observation window and a variety of Safety protection functions.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes turbulence and high uniformity, Temperature Uniformity +/- 0.0050 ℃, with multiple safety functions such as low water level protection and temperature loss protection.