Colorimetry with platinum and cobalt, measurement range 0.00~ 100PCU, resolution 0.01PCU, imported high luminance Illuminant life of 100,000 hours, Optical inspection stability, support data storage and printing functions.
Measurement range 0-50 degrees, Indication Error no more than +/- 5%, Zero calibrated and fullness calibrated, direct reading without Reagent, IP65 Protection Rating and battery powered.
Imported long-life Illuminant and narrowband filter system, Optical inspection stability, absorption value drift less than 0.002A within 20 minutes, repeability ≤ 3%, support users to calibrate Linear dispersion.
Imported long-life Illuminant and narrowband filter system, Optical inspection stability, 20 minutes drift less than 0.002A, support users to calibrate Linear dispersion, suitable for a variety of water quality testing.
Imported long-life Illuminant and narrowband filter system, Optical inspection stability, 20 minutes drift less than 0.002A; can store 10 Linear dispersion and 500 data, support USB interface upload, anti-corrosion case design.
Supports more than 30 chroma indicators, Measurement accuracy ≤ E * ab ≤ 0.01, single measurement only takes 1.5 seconds, minimum liquid addition is as low as 1ml, equipped with thermostatic sample tank and 7 inch Touchscreen.
Measurement range 0-500mg/L, no reagents and digestion, 1-2 minutes rapid determination, built-in cold light source life of 100,000 hours, support a variety of data transmission methods.
Using electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, support platinum plate and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Measurement accuracy of 0.1mN/m using electromagnetic force equilibrating Sensor, support platinum plate method and platinum ring method dual method, automatic operation without manual calculation, real-time display Linear dispersion and save data.
Using LED Illuminant to provide stable 470nm wavelength, Measurement range 0-500PCU, accuracy +/- 10PCU, support NIST traceability standard calibrated to ensure the accuracy of water quality chroma detection.
Sensor using electromagnetic force equilibrating principle, Sensitivity and high accuracy, support platinum plate method and platinum ring method, automatic measurement without calculation, surface tension Measurement range 0~ 500mN/m, accuracy 0.01mN/m, real-time display Linear dispersion and preservation results.
Using platinum plate method or platinum ring method for measurement, with 0-600mN/m wide Measurement range and 0.01mN/m high resolution, standard error +/- 0.02mN/m, equipped with large-screen LCD display and real-time Linear dispersion analysis software, support platform slow and fast lift switching.
Sensor using electromagnetic force equilibrating principle, accuracy of 0.1mN/m, platinum plate method and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Using platinum ring measurement, accuracy of 0.1mN/m, equipped with electronic level and automatic lifting system, eliminate vibration effects, support dynamic measurement and data management, to ensure experimental Repeatability and accuracy.
Using platinum ring measurement, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system to ensure stable and reliable measurement process, support dynamic smooth operation to reduce vibration interference.