Laboratory Stirrer

The agitator drives the blades to rotate via a motor, creating forced convection and shear within the container to achieve uniform mixing, dispersion, or dissolution. It is used for preparing samples such as laboratory coatings and inks, ensuring consistent distribution of components.
Selection
Select the corresponding power and speed range based on the material's viscosity; consider the corrosion resistance of the container material; match the sample capacity with the stirrer blade size; ensure speed adjustment functionality to accommodate different process requirements; pay attention to operational stability and easy-to-clean design.

Terms

Standards

Instruments

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Speed range is 300-23000 rpm, and the internal suction homogeneous structure can effectively homogenize, emulsify and extract. Stirrer can be used at low speed.

$ 296.00

Equipped with a 200mm diaMeter pick-up cylinder and an 8-liter capacity, the manual Stirrer works in tandem with an 80-mesh forming filter for uniform Pulp distribution and efficient dehydrating.

$ 1397.00

Using electronic constant force speed control circuit, digital direct display Rotation speed, Power 500W, Speed range 100-2000rpm, low reliable operation noise, can calculate the relationship between stirring line speed and chemical reaction rate.

$ 403.00

Adopt sealing solvent system to reduce water vapor interference, support 100 titration methods, Measurement range covers 1ppm to 5%, built-in automatic drift correction function, equipped with electronic adjustment Magnetic Stirrer.

$ 11389.00

Four-station independent operation does not interfere with each other, the brushless DC motor provides 12.5mN · M torque, temperature control accuracy of +/- 1 ℃, supports automatic temperature control function and stepless speed regulation of 0~ 1500rpm, to meet the needs of multi-sample synchronous processing.

$ 569.00

Maximum stirring capacity 3 liters, stirring speed 200~ 1800rpm stepless speed regulation, Heating power 450W, Temperature range RT + 5~ 320 ℃, using aluminum alloy die-casting shell, high temperature corrosion resistance easy to clean.

$ 311.00

With a maximum stirring capacity of 1000ml and 300W Heating power, stepless speed regulation can precisely and stably stir liquids within the range of 2400rpm, especially suitable for small volume sample testing, easy to operate.

$ 159.00

High torque design, Speed range 10~ 500rpm, low noise operation, suitable for high viscosity material mixing, Electric lift Travel 245mm, Stainless steel Impeller to ensure efficient mixing.

$ 496.00

Speed range 100~ 1300rpm, Max. Torque 94N.cm, large torque output at low speed, multi-stage Non-metallic gear transmission force, stable operation and low noise, suitable for a variety of Impeller.

$ 391.00

Driven by three-phase brushless DC motor, Rotation speed 50-1500rpm can be adjusted smoothly, temperature control accuracy +/- 0.5 ℃, with soft start anti-hopper and temperature protection functions, suitable for long-term unattended operation.

$ 424.00

Speed range 10~ 500rpm, lift Travel 245mm, using high torque design, especially suitable for high viscosity material mixing, can pRoduce strong hydraulic shear and high frequency mechanical effect.

$ 404.00

Rotation speed stable and no temperature rise, Max. stirring Capacity 3L, Speed range 0~ 1500rpm, suitable for small capacity single stirring needs.

$ 148.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Transverse Burst Strength Tester for the Evaluation of Impact Resistance of Corrugated Cardboard
This article explains how a lateral bursting strength tester is used to evaluate the impact resistance of corrugated cardboard. It measures the energy absorbed by the cardboard at the point of rupture using the pendulum impact principle, requiring the preparation of specimens according to standards and the control of environmental conditions during testing.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.