Standard flow Cup

The standard flow cup is used to measure the viscosity of liquids. Its principle involves recording the time it takes for a fixed volume of liquid to completely flow out through a small hole at the bottom of the cup. It is primarily used for quickly assessing the flowability of coatings and inks, and is applied in on-site quality control in fields such as printing and coating.

Instruments

Bakelite Cup body and stainless steel filter, flow time 0~ 150 seconds, flow hole diaMeter of 4mm, capacity of 100ml, in line with GB/T 1723 standard, can be used with the bracket to improve Stability.

$ 122.00

Replaceable 1-8mm aperture stainless steel filter, Cup mouth annular groove design to store overflow liquid, Cup body made of titanium anodic oxidation aluminum, outflow hole diaMeter 6mm, easy to clean and equipped with a unique serial number.

$ 420.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

The 1mm-8mm pore size filter can be replaced to meet the viscosity range test of 96~ 683cSt; the annular groove of the Cup mouth is designed to store overflowing liquids, and the Cup body is easy to clean without sinkage. It is equipped with a stainless steel filter positioner.

$ 403.00

3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.

$ 170.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, the aperture is 5mm, and the viscosity measurement range is 91~ 326cSt, which is suitable for the determination of Newton-type liquid outflow time.

$ 146.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Made of titanium anodic oxidation aluminum, the flow hole diaMeter is 8mm, the Cup height is 75mm, and each Cup is engraved with an independent serial number to ensure Measurement accuracy and durability, suitable for liquid viscosity testing.

$ 438.00

Using titanium anodic oxidation aluminum material, flow hole diaMeter 4mm, Cup height 75mm, corrosion resistance and lightweight, each Cup engraved with an independent serial number to ensure accurate and reliable measurement.

$ 438.00

Made of stainless steel, with a flow hole diaMeter of 6mm and a viscosity range of 134-685mm ²/s, it is suitable for standard viscosity testing, and the flow time is controlled between 30 and 100 seconds.

$ 143.00

Using 4mm flow hole and chrome-plated Cup structure, the outflow time range is 0-150 seconds, and the correction factor K = 1 +/- 0.03 ensures accurate and reliable viscosity measurement.

$ 115.00

The stainless steel material is durable and easy to clean, the inner wall of the Cup body is smooth to ensure the stability of Flow velocity, the diaMeter of the precision machining flow hole is 4mm, and the viscosity measurement range is 80~ 700cSt, which meets the requirements of multi-industry standards.

$ 190.00

Nozzle of stainless steel with anodic oxidation aluminum Cup body, diaMeter of flow hole 6mm, viscosity measurement range of 22-2000cSt, suitable for rapid consistency determination of Newtonian behavior liquid.

$ 388.00

Made of titanium anodic oxidation aluminum, the diaMeter of the flow hole is 2.5mm, and each Cup is engraved with an independent serial number, which is suitable for accurate measurement of liquid viscosity in the laboratory.

$ 438.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
How to Choose Between the Ring and Ball Method and the Cup and Ball Method for Softening Point Testers? Read This and Stop Worrying
This article introduces two main methods for determining the softening point of materials: the ring-and-ball method and the cup-and-ball method. The ring-and-ball method is more widely used and is suitable for materials such as asphalt. It involves measuring the temperature at which a steel ball causes the sample to sink. The cup-and-ball method is often used for specific resins or wax products, relying on the flow of the sample or the penetration of a steel ball to determine the endpoint.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.