Measurement range 50~ 1400kPa, accuracy error ≤ +/- 0.5%, fully enclosed hydraulic system to ensure high Stability, support a variety of unit conversion and thermal print output.
Using intelligent control pressure relief system, Measurement range 10~ 1600kPa, Indication Error ≤ +/- 0.5%, all-steel chain drive to improve Stability, real-time observation of test sample blasting process.
Measurement range 200~ 5600kPa, Precision ≤ +/- 0.5%, all-steel chain drive to improve Stability, three-dimensional semicircular window easy to observe the deformation process.
Using Mullen test principle, test range 250-6000kPa, accuracy +/- 1%, equipped with High Accuracy pressure sensor and automatic induction test system, 10 tests only take 65 seconds.
Measurement range covers 50~ 5600kPa, Precision up to +/- 0.5%, using all-steel chain drive and high voltage oil circuit sealing system to ensure test Stability and long life.
Using high-speed ARM processor and 32-bit High Accuracy AD converter, Measurement range 50~ 1400kPa, with over-range alarm and unplaced sample prompt function, support pressure and deformation Linear dispersion display, stable and reliable operation.
Measurement range 50~ 1600kPa, resolution 1kPa, oil feeding speed 95 +/- 5mL/min, with automatic test and sample rupture automatic stop function, support data calculation and printing report.
Adopt Mullen test principle, accuracy +/- 1%, test range 50-2000kPa, equipped with High Accuracy pressure sensor and automatic detection system, support wireless data transmission and multi-instrument Connectivity management.
Using membrane button operation and LCD liquid crystal display, Measurement range 350~ 5500kPa, resolution 1kPa, with automatic test, automatic stop and automatic calculation of multiple sets of data average function.
Adopt 24-bit High Accuracy AD converter and stable pressure sensor, Measurement range 50~ 1400kPa, with full scale alarm and 3-speed limit protection function, support a variety of Unit switches and thermal printouts.
Using 32-bit ARM processor to improve processing speed, Measurement range 250~ 5600kPa, automatic clamping system with air source operation, support pressure Linear dispersion real-time display and thermal print output.
Automatic shutdown and decompression to the initial position, one-button operation test, can store 50 sets of data and automatically calculate the average and MAX Maximum, Measurement range 204-8160kPa, Indication Error +/- 0.5% FS.
Measurement range 50~ 1400kpa, accuracy ≤ +/- 0.5%, using the method of Miao Lun, support paper, aluminum foil and non-paper sheet material detection, film convex disc pressure 9mm, upper and lower disc concentricity ≤ 0.25mm.
90 degree right angle Probe design for low headroom area operation, Measurement range 0-1500 μm, accuracy of +/- 1%, using stainless steel sealing structure to achieve complete waterproof function.
60 degree projection angle design, Measurement range 0~ 200GU, Repeatability 0.2GU, Support Automatic calibration and a variety of Measurement mode, built-in large-capacity lithium battery can work continuously for more than 12 hours.