Temperature range -60~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using equilibrate temperature control to achieve high-precision stable control, suitable for various reliability test environment.
Temperature range -20~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision stable temperature control, to meet a variety of standard test requirements.
Equipped with temperature ElectRode to achieve automatic temperature compensation, Measurement range covers 0~ 199.9ms/cm, can store 50 sets of data including number, Measured value and temperature value, microcomputer control to ensure stable measurement.
Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -60~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, 304 stainless steel studio to ensure long-term stable operation.
Using Precision Digital Sensor, Measurement speed 0.4 seconds, Temperature range -20~ 60 ℃, Humidity range 10~ 95% RH, Small size and easy to carry, with MAX Maximum hold function.
The stainless steel material is durable, the inner wall of the Cup body is smooth to ensure stable Flow velocity, the diaMeter of the flow hole is 2mm, and the viscosity range of 70cSt can be measured. Precision machining ensures measurement accuracy.
With 0.1dB high resolution and +/- 2dB Precision, supports three Frequency Weighting and four Measurement paraMeters, can store 30 sets of data and provide USB and Bluetooth output functions, suitable for a variety of noise monitoring scenarios.
Temperature Fluctuation +/- 0.05 ℃, Pump Flow rate 8L/min, with break protection and over-temperature alarm function, using Pt100 temperature sensor to ensure High Accuracy measurement.
Microcomputer and anti-interference technology implementation of rapid precision measurement, temperature range -10~ 60 ℃ error +/- 0.5 ℃, humidity range 10~ 95% RH error 2.5% +/- 1%, automatic memory MAX Maximum MIN Minimum and final measurement value.
With 0.1dB high resolution and +/- 1dB Precision, it supports three weighting options and four Measurement paraMeters, can store 30 sets of data, and provides USB and Bluetooth output functions.
Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, Pump Flow rate 8L/min, with off-couple protection and over-temperature alarm function, internal/external circulation mode, Tank volume 20L.
Temperature range -60~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using equilibrate temperature control to achieve high precision temperature control, the studio is made of 304 stainless steel to meet a variety of standard requirements.
Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.
Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.
Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, the studio is made of 304 stainless steel.