Electric Vacuum Drying Oven

The electric vacuum drying oven reduces the internal pressure by creating a vacuum, which lowers the boiling point of liquids. Combined with heating, it facilitates rapid evaporation of moisture. It is used for dehydrating heat-sensitive materials, baking electronic components, and pre-treating chemical samples, thereby preventing high-temperature oxidation.
Selection
Select the heating method based on the material's temperature resistance, determine the volume according to the amount of water to be removed, and match the vacuum pump with the appropriate pumping speed. Pay attention to the corrosion resistance of the sealing material, and note that observation windows and pressure gauges are commonly used configurations.

Terms

Standards

Instruments

With programmed vacuum cycle control, the maximum number of cycles is 99 times, and the drying time is shortened by more than 50% compared with the traditional method; equipped with a digital vacuum Gauge, the control accuracy is +/- 1% to ensure a stable vacuum environment.

$ 3294.00

Equipped with programmed vacuum cycle function, drying time is shortened by more than 50%, temperature control accuracy +/- 1 ℃, support 7 groups of 63-step Program settings, digital Vacuum Level control accuracy +/- 1%.

$ 10937.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.

$ 1003.00

The digital vacuum Gauge is used to automatically control the Vacuum Level, with an accuracy of +/- 1%; the heating element is located in the Shelf of the box to shorten the heating time by 50%; the special aluminum shelf conducts heat quickly and does not oxidize at high temperature, effectively improving the drying efficiency.

$ 1655.00

Cuboid studio improves volume utilization, drying time is reduced by more than 40%; Temperature range RT + 10~ 200 ℃, Vacuum Level 133Pa; double-decked Glass door is easy to observe, can be filled with inert gas anti-oxidation, stainless steel liner is durable and easy to clean.

$ 746.00

Cuboid studios improve space utilization, drying time is shortened by more than 40% compared with traditional equipment; double-decked tempered Glass doors are easy to observe, and mechanical Dial vacuum Meters can achieve 133Pa Vacuum Level.

$ 720.00

The vacuum environment effectively reduces the boiling point of the liquid and prevents the analysis of heat-sensitive substances; the Vacuum Level < 133Pa ensures efficient drying; the microcomputer PID control realizes accurate temperature control; the multi-layer independent heating system makes the temperature distribution more uniform.

$ 896.00

Using vacuum environment to reduce the boiling point of liquid, drying temperature RT + 10~ 250 ℃, vacuum degree of 133Pa, can effectively shorten the powder sample drying time and prevent oxidation, double-decked Glass door is easy to observe.

$ 753.00

With programmed vacuum cycle control, it can set the range of 50~ 900Pa Vacuum Level, and the drying time is shortened by more than 50%; it adopts digital vacuum Meter automatic control, accuracy +/- 1%, and supports 7 groups of 63-step temperature programming.

$ 4321.00

Cuboid Studio improves space utilization and shortens drying time by more than 40%; Double-decked Tempered Glass Door for easy observation, adjustable box door to ensure high Vacuum Level; Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa.

$ 837.00

The cuboid studio improves the volume utilization rate, the Vacuum Level control range is 10~ 105Pa accuracy +/- 1%, the programmed vacuum cycle accelerates the drying, and the 7 groups of 63-step programmable temperature control realize the whole process control.

$ 2762.00

The cuboid studio improves the effective volume utilization rate and reduces the drying time by more than 40%; the box door is made of tempered bulletproof double-decked Glass for easy observation, and the studio is made of stainless steel, which is durable and easy to clean; Vacuum Level reaches 133Pa, Temperature range RT + 10~ 200 ℃.

$ 908.00

Vacuum environment can reduce the boiling point of liquid, suitable for drying heat sensitive substances, Vacuum Level < 133Pa, temperature control accuracy +/- 0.5 ℃, effectively shorten the drying time and prevent sample oxidation or explosion.

$ 1208.00

The cuboid studio improves the volume utilization rate, and the drying time is shortened by more than 40% compared with traditional equipment. Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass doors are easy to observe, and silicon door seals ensure high vacuum maintenance.

$ 3699.00

Articles

Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.