Constant Temperature Water Bath for Ink

The ink constant temperature water bath maintains the water temperature within the set range through an electric heating and water circulation system. Ink samples are placed inside to ensure stable temperature conditions for testing properties such as viscosity and drying characteristics at different temperatures. It is commonly used in printing factories and quality inspection institutions.
Selection
When selecting, consider the temperature range and accuracy to meet testing requirements. Ensure the tank size is compatible with sample containers. Choose materials that are corrosion-resistant and provide fast heating. The operation interface should be simple, with comprehensive safety protection. Select brands and after-sales services based on the frequency of use.

Terms

Standards

Instruments

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with a built-in circulating water pump to output thermostatic water flow, stainless steel structure to ensure durability and easy cleaning.

$ 367.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

Adopt stainless steel liner and microcomputer intelligent temperature control system, Temperature Fluctuation +/- 0.2 ℃, resolution 0.1 ℃, with over-temperature water cut-off alarm function, built-in circulating water pump can output thermostatic water flow.

$ 622.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

High temperature control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, equipped with circulating pump flow ≥ 4L/min, to ensure uniform water temperature, strong corrosion resistance, compact structure, suitable for a variety of experimental scenarios.

$ 302.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120min to meet different experimental needs.

$ 740.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude of 20mm, to ensure the stability and reliability of the experimental process.

$ 740.00

Synchronized processing of 12-bit samples, temperature control accuracy of +/- 1 ℃, circular water Bath heating and independent air path adjustment. Each air needle channel can be switched on and off separately, 316 stainless steel material is corrosion resistant, suitable for a variety of testtube specifications, supports timing and over-temperature alarm functions.

$ 871.00

Articles

The Printability Tester Simulates the Effects of Different Printing Pressures on Offset Ink Transfer Rate.
This paper investigates how the printability tester simulates the effect of different pressures on ink transfer rate in offset printing.
Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance