Heat Distortion Vicat Softening Point Tester

The heat deflection and Vicat softening point tester applies a load to the sample at a constant heating rate to measure the material's performance in producing specified deformation or needle penetration depth at specific temperatures. It is used to detect the heat deflection temperature and Vicat softening point of materials such as plastics and resins, reflecting the material's resistance to deformation in a heating environment. It is applied in the evaluation of heat resistance for plastic pipes, sheets, and polymer materials.
Selection
When selecting a heat deflection temperature and Vicat softening point tester, it is essential to consider the compatibility with testing standards, such as ISO 306 or ASTM D1525. Ensure that the temperature range covers the softening interval of the material being tested, and that the load accuracy meets the requirement of ±1%. Verify that the sample holder and indenter dimensions are suitable for common specimens, and that the adjustable heating rate range includes the standard 50℃/h. The instrument should also feature automatic termination and data recording functions for ease of operation.

Terms

Instruments

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

Temperature range RT +~ 300 ℃, heating rate 120 ℃/h or 50 ℃/h, maximum deformation Measurement range 1mm, support thermal deformation and Vicat test, real-time display and alarm function.

$ 2010.00

Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.

$ 1719.00

Temperature range RT +~ 300 ℃, heating rate 120 +/- 10 ℃/h, with sample rack lifting function, automatic stop heating at the end of the test, printable report Linear dispersion, suitable for Non-metallic material testing.

$ 4059.00

The Benchtop structure supports three-station testing, and the control accuracy of the constant rate heating algorithm reaches +/- 0.5 ° C. The data can be automatically recorded and exported to Excel. Transformer oil or methyl silicone oil is used as the heat conduction medium to ensure uniform heat preservation field.

$ 2139.00

It adopts copper ring and steel ball structure, supports 2-3.55 gram steel ball configuration, and accurately determines the softening temperature of the material through the drop distance of 25.4 mm, which is suitable for all kinds of asphalt experiment needs.

$ 122.00

Dual channel simultaneous detection, Temperature range RT +~ 360 ℃, high-resolution video real-time observation and recording of the whole process, support 0.1 ℃/min -20 ℃/min continuous heating rate, easy to verify the results.

$ 5237.00

Adopt high definition camera to observe the measurement process in real time, dual-channel simultaneous detection, adjustable heating rate 0.1-20 ℃/min, support video playback and automatic interpretation of deformation characteristics.

$ 5883.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.

$ 2494.00

Six sets of independent digital PID temperature control system to achieve +/- 1 ℃ temperature control accuracy, dual cylinder design to ensure uniform pressure at both ends, Heat Seal Temperature range RT +~ 260 ℃, support layer setting can simultaneously test five sets of different paraMeter samples.

$ 2268.00

The vacuum environment can reduce the boiling point of the liquid and avoid the analysis of heat-sensitive substances; the independent temperature control laminate design realizes delamination temperature control; the stainless steel liner and the four-way heating system ensure Temperature uniformity of +/- 0.5 ℃.

$ 1760.00

Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.

$ 1003.00

The vacuum environment significantly reduces the boiling point of the liquid to below 133Pa, the temperature control accuracy reaches +/- 0.5 ° C, and supports independent temperature control of delamination; the stainless steel liner and the explosion-proof Glass door ensure the safe and efficient drying of heat-sensitive substances.

$ 2420.00

The vacuum environment significantly reduces the boiling point of liquids, handling heat-sensitive substances and preventing powder samples from moving. Temperature range is RT + 50~ 200 ℃, Vacuum Level is less than 133Pa, equipped with microcomputer intelligent control and double-decked explosion-proof Glass doors.

$ 1619.00

Articles