Manual puller

The manual pull-off tester applies mechanical force through a handle to vertically detach the bonded specimen from the substrate, measuring the maximum pull-off force at the point of failure. It is used to evaluate the adhesion strength of coatings, adhesives, and substrates, commonly employed for on-site quality inspection in the construction, automotive, and shipbuilding industries.
Selection
When selecting, consider matching the strength range of the material being tested with the capacity of the pull-out tester, confirm that the fixture size is suitable for the specimen shape, check if the pressure gauge accuracy meets testing standards, prioritize rust-resistant body materials to adapt to humid environments, and ensure that the operating handle is labor-saving and equipped with a safety locking device.

Terms

Standards

Instruments

Adopting manual sprocket drive structure, Working Travel ≥ 80mm, equipped with four weight combinations, accurate drawing is achieved through replaceable 808 stylus, and different diaMeter graphics are supported.

$ 325.00

Visual aiming and manual measurement, measurement range up to +/- 180 °, equipped with LED Illuminant to extend the service life, support 100mm/200mm ordinary testtube.

$ 444.00

Manual lifting design, Rotor speed 0.1-200/min stepless adjustable, built-in automatic temperature optimization program, up to 8 degrees/min, sample volume 10ml, repRoducibility +/- 1% F.S.

$ 5933.00

With manual and automatic temperature compensation function, Measurement range 2.00~ 4.40pHCO3, resolution 0.01pHCO3, support temperature compensation range 5.0~ 50.0 ℃, the instrument is light and beautiful.

$ 382.00

Using manual temperature compensation and imported integrated components, Measurement accuracy up to 0.01pH, Stability zero drift ≤ 0.01pH/2h, Support three point calibrating and Data storage extraction function.

$ 151.00

Adopting the national standard, the papermaking diaMeter is 200mm, and it is equipped with manual pulp board and vacuum papermaking functions, which can prepare laboratory paper samples that meet various international standards.

$ 1461.00

Rated load 1000N, Travel 100mm, manual operation is stable, can adapt to a variety of Force Gauge, suitable for tension and compression load and plug force test, horizontal structure for desktop installation.

$ 256.00

The equipment adopts international standards, the papermaking diaMeter is 300mm, the capacity is 8 liters, and it is equipped with manual pulp plate and optional vacuum papermaking function.

$ 1724.00

Full marble construction ensures Stability and rigidity, Measurement accuracy up to (3 + L/200) μm, Adjustable LED Ring Illuminant to avoid thermal deformation of the workpiece, Support manual operation and a variety of accessories options.

$ 2741.00

With manual and automatic temperature compensation function, potassium Ion concentration Measurement range 0~ 39 g/L, resolution of 0.01 pK, easy to operate, digital display intuitive, light weight only 1.5kg.

$ 382.00

With manual and automatic temperature compensation function, Measurement range 0-6 pF, resolution up to 0.01 pF, support fluorine Ion concentration value display, easy operation and digital display intuitive and accurate.

$ 262.00

5 Meters long cable design, Measurement accuracy is 0.01pH, temperature compensation mode can be selected manual or automatic, automatic temperature compensation type is equipped with 4 Probes, suitable for 0~ 60 ℃ environment.

$ 101.00

With manual and automatic temperature compensation functions, PCa Measurement range 0.00-6, resolution up to 0.01 pCa, lightweight and portable only 1.5kg, while displaying pF value and calcium Ion concentration value.

$ 382.00

The application width is more than 280mm, the thickness range of Spreader is 2um-1.1mm, and the manual drag is used to control the speed of Spreader to ensure the uniformity and accuracy of Spreader.

$ 6528.00

Measurement range 0~ 180 °, accuracy +/- 0.1 °, manual injection system to avoid bubble problems, support a variety of Measuring methods and automatic data storage, suitable for surface tension analysis.

$ 2558.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.