ISO Standard Light Box

The ISO standard light box is equipped with light sources of specific color temperatures and spectral characteristics, providing a stable lighting environment. By simulating conditions such as daylight and store lighting, it is used to compare color differences in products, ensuring consistent color evaluation under various lighting conditions. It is widely applied in color quality control across industries such as textiles, printing, and coatings.
Selection
When selecting, confirm that the light source type complies with ISO standards, such as D65 daylight. The cabinet size should be compatible with the size of the samples to be tested, and the inner walls should be neutral gray to avoid interference. Check the lamp lifespan and replacement records to ensure stable brightness. The operation interface should be simple and include a metamerism detection function. Consider environmental isolation to reduce the influence of external light.

Terms

Standards

Instruments

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

Double light source in line with ISO3664 international standards, color rendering index up to 98, with light source Timer, all-metal structure, large folio size easy to operate, accurate proofreading Color deviation.

$ 1784.00

Measurement range 35~ 135cst, flow hole diaMeter 4mm, Benchtop design with bracket, in accordance with ISO2431 standard, suitable for viscosity testing.

$ 196.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

Adopt all-metal sheet metal bracket structure, equipped with 36W × 4 reflection lamps and 36W × 4 transmission lamps, color rendering index CRI ≥ 95, tempered Glass and acrylic uniform plate make the light uniform and not dazzling, with rollers and adjustable support feet.

$ 1639.00

All-metal structure, equipped with 4 18W imported Graphica lamps, color rendering index up to 95 or more, high light uniformity, with Illuminant Timing function.

$ 538.00

Configuration of 6 Standard light sources including D65 and UV Illuminant, equipped with 45 degree observation station to achieve 45/0 observation conditions, no need to warm up without flashing, high luminous efficiency Color evaluation fast and reliable.

$ 1171.00

Equipped with five Illuminants including D65 and UV, can activate multiple Illuminants simultaneously, built-in lamp Timer, ISO 3664 and ASTM D1729 compliant.

$ 4857.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illumination up to 3000LX, life more than 10,000 hours, uniform irradiation surface and no stroboscopic, flexible adjustment of light box position and angle according to test requirements.

$ 12305.00

It adopts all-metal sheet metal structure, equipped with 4 18W high color rendering lamps, with a color rendering index of more than 95, with Illuminant Timing function, and the inclined operation table conforms to human visual observation habits.

$ 1074.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

Measurement range 320~ 685cst, flow hole diaMeter 6mm, Benchtop design with bracket, ISO2431 standard, suitable for viscosity measurement.

$ 196.00

Compliant with ISO 8502-3 standard, equipped with illuminated magnifying glass and dust comparison display panel, can accurately assess the size and distribution of surface dust, support pass test and long-term recording.

$ 367.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Short Span Compression Strength (SCT) Tester for Analyzing Paper Compression Resistance
The short-span compressive strength (SCT) tester is used to measure the resistance of materials such as paper and cardboard to compression over a short distance, primarily following international standards such as ISO 9895.
Tensile strength testing machine measures the tensile properties of paper.
The tensile strength tester is used to determine the tensile properties of paper by simulating the stretching process to obtain key parameters such as tensile strength and elongation at break. The testing follows standards such as ISO and GB to ensure reliable results.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Application of Whiteness Meter in the Evaluation of Paper Brightness and Visual Comfort
The whiteness meter quantifies the brightness and whiteness of paper by measuring its reflected light characteristics, following international standards such as ISO to ensure comparability of results. The brightness of paper affects visual comfort, and moderate whiteness can enhance the reading experience, but excessive whiteness may lead to fatigue.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.
Xenon lamp aging test chamber for testing the weather resistance of exterior wall coatings.
Xenon lamp aging test chambers accelerate the aging of exterior wall coatings by simulating environmental conditions such as sunlight, temperature, humidity, and rainfall, to evaluate their weather resistance. The tests are conducted in accordance with standards such as ISO and ASTM, controlling key parameters such as irradiance, temperature, humidity, and spray cycles.
Tensile testing machine tests the tensile strength of industrial tape.
This article explains how to use a tensile testing machine to test the tensile strength of industrial tapes. Tensile strength is a key indicator for measuring the mechanical properties of tapes, and testing must comply with international standards such as ISO and ASTM.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.