Triple-channel design can test different samples simultaneously, with a range of 0-100μm, a groove width of 12mm, and support for multiple scale units of μm, Hegman, and MIL, in line with international standards.
Using triple ceramic dialysis membrane and LT Glass Sensor membrane, Measurement range 0.00~ 12pH, support -5~ 70 ℃ sample temperature measurement, built-in temperature sensor to achieve automatic compensation, Bluetooth connection for data transmission.
Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time up to 9999 minutes, with 96 test specifications independently set and automatic defrosting function.
Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time can reach 9999 minutes. With 96 test specification settings and P.I.D automatic calculation control to ensure Test accuracy.
Using triple-channel thermal insulation structure, the damper switching time is completed within 10 seconds, and the temperature recovery time is within 5 minutes. With 96 test specification settings, the maximum Impact time is 9999 minutes, meeting the needs of high and low temperature rapid change testing.
Adopting triple-channel thermal insulation structure, the throttle switching time is completed within 10 seconds, and the temperature recovery time is completed within 5 minutes. With 96 test specification settings, the Impact time can reach 9999 minutes, and the cycle period is 9999 times, meeting the needs of High Accuracy Temperature Control.
Using three-in-one composite structure, equipped with waterproof BNC interface, Measurement range covers 0-14pH, Operating temperature 5-60 ℃, suitable for routine sample testing.
Measurement range 0-14pH, Temperature range 5-60 ℃, equipped with fiber single salt bridge liquid junction and PT-100 temperature sensor, suitable for routine sample detection.
Measurement range 0-14pH, temperature 5-60 ℃, equipped with removable protective foot, suitable for viscous sample measurement, fiber single salt bridge design to ensure measurement Stability.
Adopt horizontal three-roller extrusion grinding, roller clearance hand adjustment, maximum processing viscosity 3000000cps, roller can be cooled down water temperature control, fineness control precision, suitable for a variety of viscosity materials.
Adopt three-in-one composite structure, equipped with PT-100 temperature sensor and fiber single salt bridge, Measurement range 0-14pH, Temperature range 5-60 ℃, shell made of polycarbonic acid ester material, connector compatible with BNC interface.
Stability is maintained with 3.0 mol/L KCl filling solution, Glass bubble sensitive membrane ensures Measurement accuracy, and polycarbonic acid ester shell provides durable protection.
Double-sided design can be coated with two pre-order film thicknesses 90 and 150 μm, Spreader width 20mm, suitable for Automatic Film Applicator and Drying Time Recorder, in accordance with ASTM D 823 standard.
Complete 64 Sample Handling in 1 minute, use vertical oscillation to ensure Stability, noise is lower than 55dB, support dry grinding, wet grinding and low temperature grinding, suitable for a variety of specifications grinding tube.
Equipped with 6 independent temperature control stations, temperature control accuracy of +/- 1 ℃, support PID self-tuning function, can realize stepless speed regulation from start to 2600rpm, with triple Heating mode to adapt to different experimental needs.