The test drying oven creates a constant temperature environment through heating elements and a temperature control system, allowing moisture in the samples inside the chamber to evaporate. It is used for drying and curing, moisture determination, and stability testing of materials such as coatings and plastics, simulating the product drying process in the laboratory.
Selection
When selecting, consider the temperature range and uniformity to meet sample requirements, ensure the chamber volume fits the size of the items to be tested, and confirm that temperature control accuracy complies with experimental standards. Pay attention to the corrosion resistance of materials, ensure observation windows and ventilation designs facilitate operation, and evaluate energy consumption and maintenance costs based on actual usage frequency.

Terms

Standards

Instruments

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Using 200g weight and 1cm ² bottom area design, in line with GB/T 1728 standard, through the filter paper test method to accurately determine the film surface drying and practical drying time, easy to operate, reliable results.

$ 114.00

Using 200 +/- 0.2 g weight and 1 square centiMeter bottom area design, the drying process of the paint film was accurately determined by the cotton ball method to distinguish between surface drying and actual stages in drying.

$ 115.00

The circular track is used to automatically record the film drying process continuously, equipped with 4 kinds of specifications to choose from, the track diaMeter is 100mm, and the measurement error is +/- 0.5%, which can intuitively analyze the stages in drying state.

$ 206.00

The cuboid studio has a large effective volume utilization rate, and the drying time is reduced by more than 40% compared with the traditional Vacuum Chamber; Temperature range RT + 10~ 200 ℃, Temperature Fluctuation +/- 0.1 ℃, to ensure accurate and reliable; can be filled with inert gas to prevent oxidation.

$ 548.00

The stainless steel mirror heating Chamber and intermittent continuous heating technology are used to heat the sample evenly, with a heat-resistant temperature of more than 200 ° C. Equipped with HBM Sensor, it can remember multiple sets of drying processes and support three heating modes.

$ 612.00

Double station design can process two samples at the same time, Vacuum Level up to -0.098MPa, drying time only 4-6 minutes, suitable for rapid drying of wet paper samples with a diaMeter of no more than 200mm.

$ 4914.00

Using arc surface drying plate design, the maximum temperature can reach 180 ℃, Heating power 2500W, the steam is quickly discharged during the drying process, easy to operate and maintenance-free.

$ 1348.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Inner Chamber dimensions 450 × 450 × 450mm, Vacuum Level < 133Pa, using microcomputer temperature control technology, dual-screen digital tube display, can be filled with inert gas, suitable for drying heat-sensitive substances and explosion-proof safety.

$ 2026.00

Using infrared radiation heating, fine grinding mirror drying surface, heating power 2.0KW, maximum temperature 180 ℃, drying size 600mm × 350mm, to ensure uniform drying and smooth surface.

$ 2462.00

Vacuum heating drying technology, Vacuum Level up to -0.098MPa, pumping 80-120 liters/min, drying time is only 4-6 minutes, with intelligent PID temperature control and over-temperature alarm function, easy and safe operation.

$ 2623.00

It can measure drying time from 1 minute to 48 hours, with accuracy up to 10 seconds, and has intelligent recording function to improve the resolution of long drying process, which is suitable for various coating types.

$ 1649.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Articles

Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.