Microporous Metal Gloss Meter

The micro-hole metal gloss meter evaluates glossiness by illuminating the metal surface with a small-hole light source and measuring the intensity of the reflected light. It is used to detect the reflective properties of surfaces such as metal coatings and electroplated layers, and is applied in quality control in industries like automotive and home appliances.
Selection
When selecting, consider the matching of the measurement aperture with the sample curvature, ensure the measurement angle is suitable for the metal surface type, and verify that the instrument has a temperature compensation function. Check that the measurement range covers the actual gloss range, confirm the validity of the calibration plate's traceability certificate, and evaluate the device's environmental adaptability.

Terms

Standards

Instruments

Measurement beam of light diaMeter 1.5mm, measurement window 4mmx2mm, suitable for facet and small curvature surface measurement, low energy consumption single battery can last for more than 58 hours.

$ 428.00

Equipped with 2 * 3mm minimum measurement diaMeter, support curved surface and irregular object measurement; Adopt dual optical path technology and high-end Sensor, Repeatability up to 0.2GU; Built-in simple and statistical mode, can store 10000 data.

$ 557.00

Measurement range 20-90HC, resolution 1HC, Indication Error ≤ +/- 1HC, suitable for microporous hardness of materials testing.

$ 141.00

The pressure spring constant linear relationship, pressure needle Travel 0-2.5 mm, measurement error +/- 1HC, can be hand-held or installed measuring frame, suitable for shoe microporous hardness of materials testing.

$ 251.00

Measurement range 0~ 100HC, error +/- 1HC, suitable for the detection of microporous materials with stress above 0.049MPa when the compression rate is 50%.

$ 157.00

Suitable for medium hard resilience, rubber or microporous materials, Measurement range 0-100HE, more suitable for thinner or curved samples, can be used with handheld or supporting bench.

$ 183.00

The pressure spring is used to achieve a constant linear relationship, the pressing needle Travel 0-2.5 mm, measurement error +/- 1HC, can be used in hand or installed on the measuring rack, suitable for the test of microporous materials for shoes.

$ 525.00

Using 1.5 * 3mm Micro Measuring Area, Measurement range 0~ 1999GU, with intelligent error compensation and over 80 hours of battery life, suitable for accurate measurement of concave-convex surfaces and small areas.

$ 428.00

60 ° projection angle, Measurement range 0~ 3000GU, measurement error less than 2GU, compact and easy to carry, accurate and stable measurement, to meet the requirements of ISO and GB standards.

$ 328.00

Automatic shift design to achieve a wide range of 0-1000Gs measurement, both low Gloss and high Gloss surface detection capabilities; LED long life Illuminant and quartz crystal standard version to ensure high Stability and low annual rate of change; portable and lightweight, a battery can be used continuously for nearly 60 hours.

$ 404.00

Measurement beam of light diaMeter 1.5mm, measurement window 4mmx2mm, suitable for facet and curved surface measurement; single AA battery can work for more than 58 hours, compact and easy to carry.

$ 444.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 199.5GU, Indication Error +/- 2GU, built-in rechargeable battery can last for more than 24 hours to meet the needs of surface Gloss measurement of various materials.

$ 283.00

The 45 ° ring illumination structure is used to eliminate the direction dependence, the Inter-instrument Agreement Delta E * ab Technologies 0.2, the chromatic value Repeatability Delta E * ab 0.03, the built-in Gloss Sensor realizes the simultaneous measurement of Color Gloss, and the test port is designed to support a variety of morphological samples.

$ 9078.00

Using 20 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with elliptical measurement port and Ni-MH rechargeable battery, suitable for high Gloss object surface detection.

$ 448.00

Dual function design for simultaneous measurement of metal and Coating surface, 60 degree projection angle, Display range 0-1000 Gloss unit, resolution up to 0.1, equipped with large LCD screen and Ni-MH rechargeable battery, Stability +/- 2GU.

$ 351.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.