Split-type Gloss Meter

The split-type gloss meter evaluates glossiness by measuring the specular reflectance of light on an object's surface. With the detector separated from the main unit, it can measure complex surfaces. It is used for surface quality inspection of products such as coatings and plastics.
Selection
When selecting, consider matching the measurement angle to the sample's gloss range, check the validity of the instrument calibration certificate, confirm that the probe size is suitable for the measured area, evaluate the accessibility of the split structure to the measurement position, and verify the compliance of the measurement data with industry standards.

Terms

Standards

Instruments

Using split Probe design, Probe can be plugged and interchanged, Measurement accuracy of +/- 2% H + 1 μm, high wear-resistant carbide Probe service life of more than 500,000 times, support a variety of Calibration methods and data statistics.

$ 472.00

With split design, Probe can be plugged and interchanged, and the service life of high wear-resistant cemented carbide Probe exceeds 500,000 times. Measurement range 0-5mm, accuracy up to +/- (2% + 1μm), can accurately measure thin coatings within 10 microns.

$ 511.00

With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.

$ 107.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1250μm, support split probe flexible replacement, with automatic identification of matrix material function, minimum measurable surface radius 1.5mm.

$ 419.00

With split Probe design, equipped with F and N Probe, Measurement range 0~ 1500 microns, resolution 0.1 microns, automatic identification of substrate type, support for more than 60 readings per minute, Protection Rating IP65.

$ 1476.00

Sensor and host split design, measurement range 3-80%, accuracy +/- 0.5%, support 37 kinds of grain type measurement, with temperature and humidity compensation function, Response Time is only 1 second, Portable structure is convenient for on-site rapid detection.

$ 186.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 199.5GU, Indication Error +/- 2GU, built-in rechargeable battery can last for more than 24 hours to meet the needs of surface Gloss measurement of various materials.

$ 283.00

The 45 ° ring illumination structure is used to eliminate the direction dependence, the Inter-instrument Agreement Delta E * ab Technologies 0.2, the chromatic value Repeatability Delta E * ab 0.03, the built-in Gloss Sensor realizes the simultaneous measurement of Color Gloss, and the test port is designed to support a variety of morphological samples.

$ 9078.00

Split structure is easy to carry, supports free conversion of six Hardness units, can store 50 sets of test data, Measurement range 200~ 900HLD, with RS232 interface and backlight display function.

$ 377.00

Using 20 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with elliptical measurement port and Ni-MH rechargeable battery, suitable for high Gloss object surface detection.

$ 448.00

Adopt 45 ° circular lighting structure, reduce texture effect, compatible with 60 ° Gloss measurement, Repeatability Delta E * ab 0.03, built-in high Sensitivity Sensor, suitable for matte and textured material surfaces.

$ 6334.00

The three-angle measurement design covers 20 °/60 °/85 °, the measurement range is 0.1~ 200GU, the repeability is +/- 0.5GU, and 254 sets of data storage and Bluetooth output are supported to meet the needs of surface Gloss detection of various materials.

$ 336.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 1000GU, Repeatability 0.2GU, support USB and Bluetooth interface, can store 10000 sample data, suitable for surface Gloss measurement of various materials.

$ 332.00

Using split Sensor design, temperature range -20~ 60 ℃, humidity range 10~ 95% RH, Sampling rate 0.4 seconds, with MAX Maximum hold and automatic shutdown function, compact and easy to carry.

$ 211.00

Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, resolution up to 0.1 ℃ and 1% RH.

$ 112.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.