Dual-Beam Spectrophotometric ColoriMeter

The spectrophotometric colorimeter disperses the light source into monochromatic light through a prism or grating, irradiates the sample wavelength by wavelength, and measures the reflectance. It is used to quantify color data, control batch color differences in paint and plastic production, and detect the consistency of ink printing.
Selection
When selecting, consider matching the measurement aperture to the sample size, and ensure it includes a specular reflection mode for glossy surfaces. Check the instrument's repeatability metrics, and confirm that the accompanying software can output the required colorimetric standards. Portable models are suitable for on-site inspections, while benchtop models are ideal for laboratory environments.
Type
Measurement method
Caliber
light source
integrating sphere
Chromatic value repeability
Measurement shape
software
Special features

Terms

Standards

Instruments

Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.

$ 5237.00

1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.

$ 2494.00

Optical inspection system with dual beam of light feedback compensates for Illuminant fluctuation in real time, Light spectrum reflectance Repeatability Standard Deviation is less than 0.1%, and the inter-device difference Delta E * ab is as high as 0.08, which can accurately measure fluorescent materials without UV correction.

$ 27183.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating and imported photoelectric converter, wavelength Precision +/- 0.5nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function.

$ 4592.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function, support a variety of data map processing.

$ 4914.00

Dual beam of light path structure with 1600L/mm holographic blazing grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with Touchscreen and dedicated Software support map data processing.

$ 5883.00

Adopt dual beam of light path structure and 1600L/mm holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, equipped with color Touchscreen and special software, support a variety of data processing and comparison analysis functions.

$ 5883.00

With the integrated structure of cantilever beam simply supported beam, the carbon fiber swing Rod realizes no vibration Impact, high test accuracy, can automatically save 24 sets of data and calculate the average value, and the impact energy range covers 1J to 5.5J.

$ 1493.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octave cell sample holder to improve test efficiency, with automatic wavelength correction function and a variety of test modes.

$ 3268.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

With 0.2GU ultra-high, repeability accuracy and dual optical path technology, Measurement Angles covers 20 °, 60 °, 85 °, single machine can store 5000 pieces of data, and standard QC software is convenient for data management and export.

$ 332.00

Adopt double beam of light path structure with 1600L/mm blazing grating, stray light ≤ 0.03% T, equipped with color Touchscreen and special software, support map four arithmetic and data export function, with automatic wavelength calibrating mechanism.

$ 5399.00

Proportional double beam of light monitoring and Holographic grating, wavelength Precision +/- 0.5nm, stray light ≤ 0.15% T, support automatic zero adjustment and eight Sample Chamber linkage, easy and reliable operation.

$ 2252.00

Adopt Dual Light Path Array Sensor to Ensure Measurement Stability, Equipped with Camera Assisted Positioning System, Support Φ 8mm/Φ 4mm Dual Aperture Switching, Repeability accuracy Delta E * ab ≤ 0.03, Integrate a variety of Color Spaces and Standard light sources.

$ 4882.00

Articles