8L Tank Volume, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05 ℃, equipped with maintenance-free pressure/suction pump, supports horizontal and vertical stirring to ensure uniform thermostatic.
Adopting digital control technology, constant speed closed-loop design ensures constant power operation at low speed, Max. Torque 900mNm, maximum viscosity 30000mPa · s, supports forward and reverse rotation and adjustable timing functions.
Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.
Adopt back heating structure and horizontal forced convection technology to ensure studio Temperature uniformity. Equipped with High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.5 ° C, supports 0-9999 minutes timing function, and has multiple Safety protection mechanisms.
Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.
Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, maintenance-free pressure pump supports horizontal and vertical stirring, multiple safety protection including low liquid level and over-temperature protection.
Adopt deep closed-loop constant speed control, maintain constant Power operation at low speed; Max. Torque 650mNm, can handle liquids with viscosity up to 20000mPa · s; Rotation speed memory and timing functions.
Adopt back heating horizontal forced convection technology, Temperature Fluctuation +/- 0.5 ℃, Temperature range RT + 10~ 200 ℃. Sensor fault alarm, over-temperature protection and independent temperature limit Control system ensure the safety and reliability of the experiment.
Horizontal forced convection technology to ensure the studio Temperature uniformity, temperature control accuracy of 0.1 ℃ and Fluctuation +/- 1 ℃; Sensor fault alarm, over-temperature protection and 9999 minutes timing function, 304 stainless steel studio corrosion resistance easy to clean.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices such as low water level anti-dry burning to ensure safe and reliable operation.
Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.
Horizontal forced convection technology to ensure Temperature uniformity, temperature control accuracy of 0.1 ℃, equipped with High Accuracy Platinum Resistance Sensor and 9999 minutes timing function, suitable for a variety of non-flammable and explosive materials processing.
The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.
The use of non-heat centrifugal circulation pump to avoid the influence of self-heating, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection such as low water level to prevent dry burning, to ensure the stability and safety of the experiment.