Double-edged coating Applicator

The dual-blade applicator forms a uniform wet film on the substrate through its upper and lower blades, used for controlling coating thickness and quality inspection of paints and inks. It is suitable for laboratory sample preparation and product performance testing.
Selection
When selecting a double-edged applicator, consider factors such as the substrate type, the desired range of wet film thickness, the wear resistance of the blade material, ease of operation, and compliance with standard specifications to ensure the coating results meet practical application requirements.

Terms

Standards

Instruments

The double-edged design can simultaneously prepative 125μm and 150μm wet film thickness, U-shaped structure ensures one-time scraping completion, application width 80mm, using cr12 molybdenum vanadium material to ensure durability.

$ 138.00

Double blade design can be prepared 75μm or 100μm two wet film thickness, effective application width 80mm, using molybdenum vanadium material, suitable for film proofing.

$ 138.00

The double-sided design provides 300 and 400 μm film Film thickness, made of wear-resistant and corrosion-resistant alloy steel, Spreader width 80mm, suitable for uniform film preparation and coating performance testing.

$ 146.00

Using CR12 molybdenum vanadium material double edge structure, film thickness 500μm/600μm, U-shaped design to achieve fast Spreader, effective application width 80mm, total length 100mm, suitable for wet-film preparatory.

$ 138.00

Made of wear-resistant and corrosion-resistant alloy steel, the double-sided design provides two film Film thicknesses of 70 and 100 μm, and the Spreader width is 80mm, which is suitable for experimental film preparation of various materials.

$ 146.00

Double-sided design provides 25/50μm two kinds of wet film thickness, Spreader width 80mm, wear-resistant corrosion-resistant alloy steel material to ensure long-term use Stability, suitable for a variety of material film experiments.

$ 146.00

Double-sided design can provide 75/150μm two kinds of wet film thickness, effective Spreader width 12.7mm, wear-resistant corrosion-resistant alloy steel material to ensure accurate control of film Film thickness, to ensure coating conformity and Repeatability.

$ 130.00

Adopt bar and Drawdown blade double coating method, Spreader accuracy +/- 0.003mm, coating speed 1~ 300mm/s stepless speed regulation, equipped with Vacuum chuck and heating function, closed-loop motor drive to ensure stable scraping.

$ 5237.00

Equipment provides bar and adjustable drawdown blade two coating methods, Spreader thickness range 0~ 10mm, coating speed 5~ 180mm/s, support custom Coating size 500 * 1000mm, suitable for a variety of substrates.

$ 8142.00

Double-sided different film Film thickness design, wet film thickness 150/200μm, Spreader width 80mm, wear-resistant corrosion-resistant alloy steel material, suitable for a variety of materials experimental film preparatory.

$ 146.00

Using CR12 molybdenum vanadium material to ensure durability, providing 75-600μm multi-film thickness range, double-sided design can complete different thickness Spreader at one time, effective application width 80mm to meet the requirements of standard samples.

$ 293.00

Adopt drawdown Bar & Blade double coating method, Spreader accuracy up to +/- 0.003mm, heating Temperature range RT +~ 180 ℃, equipped with air knife function, ensure Spreader uniform and stable.

$ 3785.00

Adopt drawdown Bar & blade double coating method, coating speed 1-300mm/s stepless speed regulation, equipped with Vacuum chuck and heating function, closed-loop motor to precisely control the scraping distance and speed.

$ 4108.00

Drawdown blade and bar double coating method, coating speed 1~ 300mm/s stepless speed, film thickness control accuracy +/- 0.001mm, equipped with Vacuum chuck and heating function, closed-loop motor drive to ensure stable scraping.

$ 5237.00

Drawdown blade and bar double coating method, coating speed 1~ 300mm/s stepless speed, film thickness control accuracy +/- 0.001mm, with Vacuum chuck and heating function, closed-loop motor drive precise control of scraping distance and speed.

$ 4592.00

Articles

Comparison of Selection Between Dual-Column Gantry and Single-Column Universal Testing Machines for Plastic and Rubber Testing
This article compares the differences between dual-column portal and single-column universal testing machines in plastic and rubber testing. Dual-column portal types offer high rigidity and large load capacity, making them suitable for high-strength materials and high-precision testing; single-column types have an open structure and low cost, making them ideal for small loads and frequent fixture changes.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.
Inventory of Laboratory Coating Instruments
Laboratory coating tools include gap coaters, wire rods, automatic coating machines, etc. What are the differences between them? This article will tell you!
How to Prepare Precise Film Layers Using a Laboratory Film Coating Machine
Precise film preparation can effectively eliminate human operational errors by rationally selecting applicators (wire rods or blades) that match the material's rheological properties and precisely controlling coating speed, environmental temperature and humidity, and substrate conditions.