Precision Constant Temperature Dual Chamber

The precision constant temperature dual bath features two independent temperature control chambers, each capable of being set to different temperatures. It utilizes a circulation pump along with heating and cooling systems to maintain stable liquid conditions within the baths. This instrument is suitable for applications requiring dual-temperature environments, such as viscosity testing of coatings and drying experiments of inks, ensuring that samples undergo comparative testing under specific temperature differentials.
Selection
When selecting, focus on the temperature control range and accuracy to match experimental requirements; the tank capacity should accommodate sample sizes; check parameters for temperature uniformity and fluctuation; confirm the corrosion resistance of the tank material; the circulation pump flow rate must meet heat transfer efficiency requirements; the operation interface should be simple and user-friendly.

Terms

Standards

Instruments

Single Precision Sensor for Fast Response and Durability, with 0.01g/0.02g Readability and Automatic Dual Range function, supports six-level filter adjustable and multiple weighing modes to ensure high conformity and sensitive and stable compatibility.

$ 1542.00

Temperature range -20~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision stable temperature control, to meet a variety of standard test requirements.

$ 9405.00

Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -60~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, 304 stainless steel studio to ensure long-term stable operation.

$ 5132.00

Temperature range -60~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using equilibrate temperature control to achieve high-precision stable control, suitable for various reliability test environment.

$ 6652.00

Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.

$ 2090.00

Single Precision mass Sensor, with 0.1mg + 0.01mg Readability and Automatic Dual Range Function, Fast Response and High Stability, Supports Multiple Weighing Modes and Unit Conversion.

$ 2502.00

Single Sensor technology implementation is compatible with Fast Response and Stability, with 1/2mg Readability and Dual Range function, supports six filter adjustment and twenty weighing Unit switches.

$ 1655.00

The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.

$ 877.00

Using Single Precision Sensor Technology, Response Time is Fast and Stability, with 1/2mg Readability and Six-level Filter Adjustable, Supports Multiple Weighing Modes such as Percentage and Density Direct Reading.

$ 1542.00

Single precision mass Sensor, Response fast and durability; with six shock filter adjustable function, support dual range double accuracy adjustable, stable time adjustable, suitable for a variety of complex weighing environment.

$ 3688.00

Readability up to 1mg, Capacity 200g, with LCD backlight display, AC and DC dual-use, full scale peeling, counting function and a variety of unit conversion, Stabilization time ≤ 3 seconds, suitable for precision weighing environment.

$ 356.00

Using high precision Sensor, weighing accurate and stable, repeatability error 0.2g, Linearity 0.3g. Configure battery to realize AC and DC dual-use, LCD with backlight display, with weighing, peeling, counting, unit conversion and other functions.

$ 122.00

Adopt High Precision Sensor to ensure accurate and stable weighing, configure battery to support AC and DC dual-use, 0.01g High Accuracy and ≤ 3 seconds Fast Response, with weighing, peeling, counting, unit conversion and other functions, front horizontal bubble is easy to adjust.

$ 130.00

Single Sensor technology implementation Fast Response and stability compatible, with 0.01g/0.02g Readability and automatic dual range function, support six filter adjustable and a variety of weighing modes.

$ 1429.00

Temperature range -60~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using equilibrate temperature control to achieve high precision temperature control, the studio is made of 304 stainless steel to meet a variety of standard requirements.

$ 6234.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.