Brookfield ViscoMeter

A rotational viscometer calculates viscosity based on the resistance encountered by a rotor rotating in the sample. It is used for measuring the viscosity of fluids such as coatings and inks, guiding adjustments in production processes and quality control.
Selection
When selecting, consider matching the measurement range with the sample viscosity, ensuring the rotor model suits the sample characteristics, having adjustable speed to meet different shear rate requirements, maintaining temperature control for measurement accuracy, and using corrosion-resistant materials to adapt to the testing environment.

Terms

Standards

Instruments

Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.

$ 183.00

The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.

$ 204.00

Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.

$ 135.00

Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.

$ 185.00

Measurement accuracy +/- 2%, equipped with 5 calibrated oils to ensure measurement accuracy, as a special accessory for cone-plate viscoMeter to achieve stability testing.

$ 2953.00

The shear rate is 2.0N, only 0.5ml sample volume can be completed to complete the test, suitable for a variety of models of Viscometer host, to meet the measurement needs of different viscosity ranges.

$ 683.00

Provides accurate viscosity values of 5.7cp, 400ml per bottle for Viscometer calibrated measurement Stability and Reliability.

$ 185.00

Range 5-50p, accuracy of +/- 2%, equipped with 5 kinds of special calibrated oil to ensure measurement accuracy, as the core component of cone-plate viscoMeter to ensure test Stability.

$ 2931.00

Shear rate 3.84N, sample size only 0.5ml, suitable for a variety of Viscometer models, ensuring High Accuracy measurement and wide applicability.

$ 683.00

Silicone oil standard liquid viscosity value 11000cp, capacity 400ml, specially designed for Viscometer calibrated, providing stable and reliable viscosity reference standards.

$ 204.00

Measurement range 2~ 1000000mPa · s, accuracy +/- 5% F. S, equipped with two rotor groups II and III, support 7.5/75/750rpm third gear Rotation speed, suitable for a variety of fluid viscosity measurement.

$ 590.00

Can measure the dynamic viscosity of normal temperature solid high temperature molten fluid, viscosity range 10~ 200000mPa · s, Temperature range RT +~ 250 ℃, repRoducibility +/- 0.5% F. S, support a variety of Rotor speed and timing functions.

$ 1476.00

Micro vibration technology implementation viscosity measurement, range 0-5000mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, with IP68 Protection Rating and a variety of connection methods.

$ 7335.00

Using Dial display and manual Rotation speed control, Measurement accuracy of +/- 5%, viscosity range of 10 to 2000000mPa · s, support for a variety of rotor specifications and Rotation speed switching, suitable for a variety of fluid Tack test.

$ 643.00

Equipped with 7-inch Touchscreen for easy operation, anti-static shell design is safe and reliable, viscosity measurement range 1~ 1500000mPa · s, support automatic conversion of power and kinematic viscosity, built-in temperature Probe to ensure accurate data.

$ 2232.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.