Spectrophotometric Chromaticity Meter

The spectrophotometer analyzes color data by measuring the spectral composition of light reflected or transmitted by an object. It is used for color quality control, formula matching, and color difference detection in industries such as coatings and plastics.
Selection
When selecting a spectrophotometer, considerations should include measurement geometry, spectral range, instrument-to-instrument consistency, sample adaptability, and software functionality to ensure compliance with specific industry standards and operational requirements.

Terms

Standards

Instruments

Using Spectrophotometric method, spectra-trophotometry to detect nickel concentration, detection limit of 0.1mg/L, equipped with imported cold light source life of 100,000 hours, support a variety of Measurement mode and wireless data transmission function.

$ 816.00

Based on o-phenanthroline Spectrophotometric method, spec-trophotometry, the detection limit is up to 0.01mg/L, the imported cold light source does not need to be preheated, and supports continuous Measurement mode. Colorimetric integrated tube operation is safe and fast.

$ 816.00

Adopt 165 ℃ thermostatic digestion and spectrophotometric detection technology, detection range 0~ 20000mg/L, support digestion Colorimetric integrated tube design, built-in rechargeable battery, can store 4000 sets of data and support a variety of transmission interfaces.

$ 2526.00

Adopt horizontal press measurement and physical positioning observation window, density Repeatability ≤ 0.001D, chroma Repeatability dE * ab ≤ 0.03, provide nearly 30 kinds of Measurement parameters and more than 30 kinds of evaluation Illuminants, and support connection PC software and mobile end applications.

$ 3285.00

Using imported cold light source and narrow-band interference technology, the detection limit is 0.05mg/L, supports continuous measurement and standard Measurement mode, and the built-in large-capacity lithium battery can store 4000 sets of data.

$ 816.00

Using ammonium molybdate Spectrophotometric method, spec-trophotometry, the detection limit is as low as 0.02mg/L, the measurement can be completed within 15-20 minutes without digestion, and supports a variety of transmission interfaces and data processing functions.

$ 816.00

The imported cold light source has a lifespan of 100,000 hours, a detection limit of 0.05mg/L, supports continuous Measurement mode and data storage 4000 groups, and the operation is simple, fast and safe.

$ 816.00

Using Spectrophotometric method, specs-trophotometry to detect nickel content, Measurement range 0.00-7 g/L, accuracy +/- 0.10g/L, equipped with LED@575nm Illuminant, easy to operate without complex pretreatment, suitable for rapid batch detection needs.

$ 215.00

The imported cold light source has a lifespan of 100,000 hours, a detection limit of 0.04mg/L, and supports 4000 groups of continuous Measurement mode and data storage. The operation of the digestion Colorimetric integrated tube is safe and convenient.

$ 816.00

Using Spectrophotometric method, spectra-trophotometry detection, the minimum display value is 0.001mg/L, the imported cold light source life is 100,000 hours, supports a variety of Measurement modes and wireless transmission, intelligent operation and low cost of consumables.

$ 816.00

The imported cold light source does not need to be preheated for 100,000 hours, the detection limit is 0.01mg/L Sensitivity is high, the standard and continuous Measurement mode are supported, and the digestion Colorimetric integrated tube is safe and fast to operate. It can store 4000 sets of data and support a variety of transmission methods.

$ 816.00

Spectrophotometric method, spectra-trophotometry detection, minimum display value of 0.001mg/L, Optical inspection Stability of +/- 0.001A/20 minutes, support continuous measurement and standard measurement dual mode, no reagents and digestion process, detection time only 1-2 minutes.

$ 816.00

Imported cold light source technology life of 100,000 hours, support 0.001mg/L high Sensitivity detection, with digestion Colorimetric integrated tube design to achieve safe and fast measurement, can store 4000 sets of data and support multi-mode power supply.

$ 2946.00

Using imported cold light source, Optical inspection Stability up to +/- 0.001A/20min, life 100,000 hours; Colorimetric digestion integrated tube design, support a variety of heavy metals detection, minimum detection value of 0.001mg/L.

$ 3268.00

Using fluorine reagent Spectrophotometric method, spec-trophotometry detection, the detection limit is 0.02mg/L, equipped with imported cold light source life 100,000 hours, supports a variety of data transmission interfaces, built-in 4000 sets of data storage, the use of digestion Colorimetric integrated tube operation is safe and convenient.

$ 816.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
The role of spectrophotometers in ink color matching
The spectrophotometer objectively quantifies color by measuring the spectral data of ink. Based on the Lambert-Beer law, it converts color into calculable spectral values, replacing traditional methods that rely on the human eye and experience.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Determination of Chromaticity Value of Pulp by Spectrophotometry
This article introduces the method for determining pulp chromaticity using spectrophotometry. It first explains the importance of chromaticity for pulp quality, then details the basic principles of spectrophotometry, which quantifies color by measuring the reflection of light from the pulp, typically expressed using the CIELAB color system.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.